Single-Center Experience on the Elective Hybrid Combination of Single Perclose + Angio-Seal VIP 8F Compared With Standard Dual Perclose During Percutaneous Endovascular Aortic Aneurysm Repair.

Paolo Spath,Filippo Maioli, Federica Campana, Teresa Gabellini, Annalisa Perulli, Michele Leone, Francesco Giacchi, Giacomo Di Iasio, Massimiliano Marini, Silvia Massini, Sara Pomatto,Cecilia Angherà, Salvatore Tarantini

Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists(2024)

Cited 0|Views0
No score
Abstract
PURPOSE:This single-center study aimed to assess patients who underwent intentional percutaneous endovascular aortic aneurysm repair (pEVAR) with Hybrid Technique combining a single Perclose (Abbott, Abbott Park, Illinois) Suture-Mediated Closure Device + single Angio-Seal VIP 8F (Terumo, Tokyo, Japan) and compare outcomes with the standard Dual Perclose technique. Materials and Methods: Consecutive elective pEVAR patients treated from November 2022 to November 2023, with healthy femoral accesses and introducer sheaths ≤20 French (F) outer diameter, were included. Coin-toss randomization determined whether a combination of single Perclose Device + single Angio-Seal VIP 8F (Hybrid Technique) or the standard double Perclose Devices (Dual Perclose) was used. In Hybrid Technique, a single Perclose device was positioned at 12 o'clock; a single Angio-Seal VIP 8F was placed after sheaths removal. Dual Perclose followed standard procedure. Primary endpoints included immediate hemostasis, sheath diameter differences, access conversion rate, technical success, and cost analysis. RESULTS:The study involved 60 pEVAR patients (median age=78, interquartile range [IQR]=72-85 years) within the inclusion criteria. In 14 (24%) cases, only 1 femoral access was studied. There were 106 pEVAR accesses, with 58 (54.7%) in the Hybrid Technique group and 48 (45.3%) in the Dual Perclose group. Both groups exhibited homogeneity in pre-operative characteristics and sheath diameter (Hybrid Technique-16F vs Dual Perclose-18F; p=0.202). Immediate hemostasis was achieved in 100% of the Hybrid Technique group vs 87.5% for the Dual Perclose group (p=0.006). Surgical access conversion was unnecessary. Technical success was 100%, with all 6 femoral bleeding cases after Dual Perclose resolved endovascularly, using additional devices. Cost analysis showed a median cost of 330 euros (IQR=0) for the Hybrid Technique group vs 384 euros (IQR=360-456) for the Dual Perclose group (p<0.001). Thirty-day mortality was 3%, in 2 fragile patients, without access-related complications. Multivariate analysis identified Dual Perclose access (odds ratio [OR]=35.6; 95% confidence interval [CI]=18.3-36.8; p<0.001) and obesity (OR=19.7; 95% CI=1.4-23.9.5; p<0.001) as independent risk factors for immediate hemostasis failure. Median follow-up was 134 days (IQR=41-227), with 1 Hybrid Technique case (2%) successfully treated with thrombin injection for a small femoral pseudoaneurysm after 62 days. CONCLUSIONS:The elective Hybrid Technique with combination of single Perclose Device + single Angio-Seal VIP 8F during pEVAR in selected patients appears to be non-inferior to the standard Dual Perclose procedure. It demonstrates a positive trend in reducing immediate hemostasis failure and costs. Both procedures achieved technical success and avoiding surgical access conversions. CLINICAL IMPACT:This study introduces a novel elective hybrid technique combining a single Perclose device with a single Angio-Seal VIP 8Fr for percutaneous endovascular abdominal aortic interventions. Results for hybrid technique showed 100% technical success and efficient immediate hemostasis, while costing less than standard dual Perclose procedure. Both procedures did not require surgical conversions. Despite being a single-center study, it demonstrates potential benefits of the intentional application of this hybrid technique towards minimally invasiveness. Obesity and dual Perclose technique were identified as independent risk factors for hemostasis failure, reaffirming the hybrid technique procedure's efficacy as well as and non-inferiority to standard procedure.
More
Translated text
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined