Early changes in corneal densitometry after FS-LASIK combined with accelerated corneal cross-linking for correction of high myopia.

Qing-Bao Wang,Hong-Sheng Bi, Xiao-Fan Wang, Hua Fan, Li Li, Peng Ji

International journal of ophthalmology(2024)

引用 0|浏览0
暂无评分
摘要
AIM:To observe the effects of femtosecond laser-assisted excimer laser in situ keratomileusis combined with accelerated corneal cross-linking (FS-LASIK Xtra) on corneal densitometry after correcting for high myopia. METHODS:In this prospectively study, 130 patients underwent FS-LASIK or FS-LASIK Xtra for high myopia. Their right eyes were selected for inclusion in the study, of which 65 cases of 65 eyes in the FS-LASIK group, 65 patients with 65 eyes in the FS-LASIK Xtra group. Patients were evaluated for corneal densitometry at 1, 3, and 6mo postoperatively using Pentacam Scheimpflug imaging. RESULTS:Preoperative differences in corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups in different ranges were not statistically significant (P>0.05). Layer-by-layer analysis revealed statistically significant differences in the anterior (120 µm), central, and total layer corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups at 1 and 3mo postoperatively (all P<0.05), the FS-LASIK Xtra group is higher than that of the FS-LASIK group. Analysis of different diameter ranges showed statistically significant differences between the FS-LASIK group and the FS-LASIK Xtra group at 1mo postoperatively in the ranges of 0-2, 2-6, and 6-10 mm (both P<0.05); At 3mo postoperatively, the FS-LASIK Xtra group is higher than that of the FS-LASIK group in the ranges of 0-2 and 2-6 mm (P<0.05). At 6mo postoperatively, there were no statistically significant differences in corneal densitometry between the FS-LASIK group and the FS-LASIK Xtra group in different diameter ranges (all P>0.05). CONCLUSION:There is an increase in internal corneal densitometry during the early postoperative period after FS-LASIK Xtra for correction of high myopia. However, the densitometry values decreased to the level of conventional FS-LASIK at 6mo after surgery, with the most significant changes observed in the superficial central zone.
更多
查看译文
关键词
femtosecond laser,accelerated corneal cross-linking,corneal densitometry,high myopia,femtosecond laser in situ keratomileusis
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要