谷歌浏览器插件
订阅小程序
在清言上使用

Microneedle electrochemical sensor based on disposable Stainless-Steel Wire for Real-time Analysis of Inole-3-acetic acid and Salicylic acid in Tomato Leaves Infected by Pst DC3000 in situ

Lingjuan Tang,Daodong Li, Wei Liu, Yihui Tang, Rongcheng Zhang, Yiran Tian, Rong Tan,Xiaolong Yang, Lijun Sun

Analytica Chimica Acta(2024)

引用 0|浏览0
暂无评分
摘要
Background Indole-3-acetic acid (IAA) and salicylic acid (SA), pivotal regulators in plant growth, are integral to a variety of plant physiological activities. The ongoing and simultaneous monitoring of these hormones in vivo enhances our comprehension of their interactive and regulatory roles. Traditional detection methods, such as liquid chromatography-mass spectrometry, cannot obtain precise and immediate information on IAA and SA due to the complexity of sample processing. In contrast, the electrochemical detection method offers high sensitivity, rapid response times, and compactness, making it well-suited for in vivo or real-time detection applications. Results A microneedle electrochemical sensor system crafted from disposable stainless steel (SS) wire was specifically designed for the real-time assessment of IAA and SA in plant in situ. This sensor system included a SS wire (100μm diameter) coated with carbon cement and multi-walled carbon nanotubes, a plain platinum wire (100 μm diameter), and an Ag/AgCl wire (100 μm diameter). Differential pulse voltammetry and amperometry were adopted for detecting SA and IAA within the range of 0.1–20 μM, respectively. This sensor was applied to track IAA and SA fluctuations in tomato leaves during PstDC3000 infection, offering continuous data. Observations indicated an uptick in SA levels following infection, while IAA production was suppressed. The newly developed disposable SS wire-based microneedle electrochemical sensor system is economical, suitable for mass production, and inflicts minimal damage during the monitoring of SA and IAA in plant tissues. Significance This disposable microneedle electrochemical sensor facilitates in vivo detection of IAA and SA in smaller plant tissues and allows for long-time monitoring of their concentrations, which not only propels research into the regulatory and interaction mechanisms of IAA and SA but also furnishes essential tools for advancing precision agriculture.
更多
查看译文
关键词
Microneedle electrochemical sensor,Disposable stainless steel wire,Indole-3-acetic acid,Salicylic acid,Real-time and in situ electrochemical detection
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要