谷歌浏览器插件
订阅小程序
在清言上使用

Efficient Separation of Organic Anions in Beverages using Aminosilane-Functionalized Capillary Electrophoresis with Contactless Conductivity Detection

Analytica Chimica Acta(2024)

引用 0|浏览1
暂无评分
摘要
Background Capillary electrophoresis (CE) has the advantage of rapid anion analysis, when employing a reverse electroosmotic flow (EOF). The conventional CE method utilizes dynamic coatings with surfactants like cetyltrimethylammonium bromide (CTAB) in the run buffer to reverse the EOF. However, this method suffers from very slow equilibration leading to drifting effective migration times of the analyte anions, which adversely affects the identification and quantification of peaks. Permanent coating of the capillary surface may obviate this problem but has been relatively little explored. Thus, permanent capillary surface modification by the covalent binding of 3-aminopropyltriethoxysilane (APTES) was studied as an alternative. Results This study investigates the effect of APTES concentration for surface functionalization on EOF mobility, separation efficiency, and reproducibility of anion separation. The performance data was complemented by X-ray photoelectron spectroscopy (XPS) and contact angle (CA) measurements. The XPS measurements showed that the coverage with APTES was dependent on its concentration in the coating solution. The XPS measurements correlated well with the EOF values determined for the capillaries tested. A standard mixture of 21 anions could be baseline separated within 10 minutes in the capillaries with lower EOF, but not in the capillary with the highest EOF as the residence time of the analytes was too short in this case. Compared to conventional dynamic coating with CTAB, APTES-functionalized capillaries provide faster equilibration and long-term EOF stability. The application of APTES-functionalized capillaries in analyzing different beverages demonstrates the precision, reliability, and specificity in determining organic anions, providing valuable insights of their compositions. Significance APTES coating on capillaries provides a facile approach to achieve a permanent reversal of the stable EOF to determine anions. The control of the coverage via the concentration of the reagent solution allows the tailoring of the EOF to different needs, a faster EOF for less complex samples where resolution is not challenging, while a lower EOF for higher complex samples where the focus is on separation efficiency. This enhancement in efficiency and sensitivity has been applied to analyzing organic acids in several beverages.
更多
查看译文
关键词
APTES-functionalized capillary,Reversed EOF,Anion separation,Surface Modification,Beverages,CE-C4D
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要