谷歌浏览器插件
订阅小程序
在清言上使用

Measurement of Energy Resolution with the NEXT-White Silicon Photomultipliers

T. Contreras, B. Palmeiro, H. Almazán, A. Para, G. Martínez-Lema, R. Guenette, C. Adams, V. Álvarez, B. Aparicio, A. I. Aranburu, L. Arazi, I. J. Arnquist, F. Auria-Luna, S. Ayet, C. D. R. Azevedo, K. Bailey, F. Ballester, M. del Barrio-Torregrosa, A. Bayo, J. M. Benlloch-Rodríguez, F. I. G. M. Borges,A. Brodolin, N. Byrnes, S. Cárcel, A. Castillo, S. Cebrián, E. Church, L. Cid, C. A. N. Conde, F. P. Cossío, E. Dey, G. Díaz, T. Dickel, C. Echevarria, M. Elorza, J. Escada, R. Esteve, R. Felkai, L. M. P. Fernandes, P. Ferrario, A. L. Ferreira, F. W. Foss, Z. Freixa, J. García-Barrena, J. J. Gómez-Cadenas, R. González, J. W. R. Grocott, J. Hauptman, C. A. O. Henriques, J. A. Hernando Morata, P. Herrero-Gómez, V. Herrero, C. Hervés Carrete, Y. Ifergan, B. J. P. Jones, F. Kellerer, L. Larizgoitia, A. Larumbe, P. Lebrun, F. Lopez, N. López-March, R. Madigan, R. D. P. Mano, A. P. Marques, J. Martín-Albo, M. Martínez-Vara, R. L. Miller, K. Mistry, J. Molina-Canteras, F. Monrabal, C. M. B. Monteiro, F. J. Mora, K. E. Navarro, P. Novella, A. Nuñez, D. R. Nygren, E. Oblak, J. Palacio, I. Parmaksiz, A. Pazos, J. Pelegrin, M. Pérez Maneiro, M. Querol, A. B. Redwine, J. Renner, I. Rivilla, C. Rogero, L. Rogers, B. Romeo, C. Romo-Luque, F. P. Santos, J. M. F. dos Santos,M. Seemann, I. Shomroni, P. A. O. C. Silva, A. Simón, S. R. Soleti, M. Sorel, J. Soto-Oton, J. M. R. Teixeira,S. Teruel-Pardo, J. F. Toledo, C. Tonnelé, J. Torrent, A. Trettin, A. Usón, P. R. G. Valle, J. F. C. A. Veloso, J. Waiton, A. Yubero-Navarro

arxiv(2024)

引用 0|浏览13
暂无评分
摘要
The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses ^83mKr data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 ± 0.6) %, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要