Application of chimeric antigens to paper-based diagnostics for detection of West Nile virus infections of Crocodylus porosus – a novel animal test case

biorxiv(2024)

Cited 0|Views3
No score
Abstract
Laboratory-based diagnostics like plaque reduction neutralization tests (PRNT) and ELISA are commonly used to detect seroconversion to flavivirus infections. However, faster, qualitative screening methods are needed for quicker diagnosis and better patient outcomes. Lateral flow assays (LFAs) can provide rapid results (5-15 mins) at the point-of-care, yet few commercial flavivirus antibody detection LFAs are available. We developed an LFA using novel chimeric viral antigens produced by genetically modifying the mosquito restricted Binjari virus (BinJV) to display the outer virion proteins of pathogenic viruses such as West Nile virus (WNV). The BinJV chimeric platform offers various advantages for diagnostic assay development, including rapid construction of new chimeras in response to emerging viral variants, safe, scalable antigen manufacturing, and structural indistinguishability to the wild-type pathogenic virion. As a demonstration of feasibility, we applied chimeric WNV (BinJV/WNV) antigen to LFA as the capture/test line reagent for detection of seroconversion of crocodilians to WNV – a virus affecting crocodilians on multiple continents. We verified the antigenic conservation of the chimera when applied to the LFA detection surface using monoclonal antibodies. Using well-characterised sera (n=60) from WNV seropositive or flavivirus naive Australian saltwater crocodiles ( Crocodylus porosus ), we illustrated 100% sensitivity and specificity, with results achieved in less than 15 minutes. The LFA further accurately detected seroconversion in animals experimentally infected with WNV. This qualitative screening method can be performed both inside and outside of a laboratory, and the assay design will guide the optimization of similar tests for vector borne virus infection detection in both humans and other animals. ### Competing Interest Statement Data included in this publication are based on a patent (WO/2018/176075) on which J.J.H., H.B.O., R.A.H., and J.H.-P are inventors. J.Mac. is founder and co-director of BioCifer Pty Ltd. The funders had no role in the study, design, collection, analysis, or interpretation of data; in the writing of the manuscript, or in the decision to publish this article. The remaining authors declare no conflicts of interest.
More
Translated text
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined