Reliability and reference values for diaphragmatic excursion, thickness, and thickening fraction and quadriceps femoris muscle thickness in full-term newborns evaluated by ultrasound

Milena Siciliano Nascimento, Flávia Sales Leite, Patricia Angelica L. Silva, Gisele Cristina Zamberlan, Priscila Monteiro de Souza,Raquel Afonso Caserta Eid, Romy Schmidt B. Zacharias,Cristiane do Prado,Carla Luciana Batista

European Journal of Pediatrics(2024)

引用 0|浏览0
暂无评分
摘要
To determine the diaphragm thickness, thickening fraction, and excursion and thickness of the quadriceps femoris muscle in full-term newborns and to evaluate the intra- and interrater reliability of these measurements. This was a prospective, observational clinical study including full-term newborns born within the first 48 h after birth. Serial measurements of the thickness, thickening fraction, and mobility of the diaphragm muscles and the thickness of the quadriceps muscle were obtained using ultrasound images. A total of 69 newborns with a mean gestational age of 39 weeks were included. The following measurements were obtained and are expressed as the mean (standard deviation): inspiratory diaphragm thickness, 0.19 cm (0.04); expiratory diaphragm thickness, 0.16 cm (0.04); diaphragm thickness fraction, 16.70 cm (10.27); diaphragmatic excursion, 0.68 cm (0.22); and quadriceps thickness, 0.99 cm (0.14). Intrarater reliability was assessed using intraclass correlation coefficients (ICCs). Excellent intrarater agreement was observed for the two groups of operators (ICC > 0.86, p < 0.001) for all measurements except for the diaphragm thickening fraction, which showed good agreement for both operator groups (ICC = 0.70, p < 0.001). Regarding interrater reliability, moderate agreement between the raters was observed in the means of all measures (ICC > 0.49, p < 0.001), except for the diaphragm thickening fraction, which showed poor agreement. Conclusion: Good intrarater and moderate interrater reliability were achieved in ultrasound evaluations of the thickness and mobility of the diaphragm and quadriceps femoris muscles in full-term newborns, demonstrating the feasibility of this technique for clinical use. This pioneering study offers reference values for these muscles in a single study, allowing comparisons between different clinical conditions.
更多
查看译文
关键词
Ultrasound,Full-term newborn,Diaphragm thickness,Diaphragm thickening fraction,Quadriceps thickness
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要