Photoluminescence-based biosensor for the detection of antibodies against SARS-CoV-2 virus proteins by ZnO tetrapod structure integrated within microfluidic system

Science of The Total Environment(2024)

引用 0|浏览1
暂无评分
摘要
This paper reports on development of an optical biosensor for the detection of antibodies against SARS-CoV-2 virus proteins in blood serum. ZnO nanotetrapods with high surface area and stable room temperature photoluminescence (PL) were selected as transducers. Structure and optical properties of the ZnO tetrapods have been studied by XRD, SEM and Raman spectroscopy. Crystallinity, dimensions and emission peaks of the ZnO tetrapods were determined. The ZnO tetrapods were fixed on glass chip. Silanization of ZnO tetrapods surface resulted in forming of functional surface groups suitable for the immobilization of bioselective layer. Two types of recombinant proteins (rS and rN) have been used to form bioselective layer on the surface of the ZnO tetrapods. Flow through microfluidic system, integrated with optical system, has been used for the determination of antibodies against SARS-CoV-2 virus proteins present in blood samples. The SARS-CoV-2 probes, prepared in PBS solution, have been injected into the measurement chamber with a constant pumping speed. Steady-state photoluminescence spectra and photoluminescence kinetics have been studied before and after injection of the probes. The biosensor signal has been tested to anti-SARS-CoV-2 antibodies in the range of 0.001 nM–1 nM. Control measurements have been performed with blood serum of healthy person. Sensitivity tests showed that ZnO-SARS-CoV-2-rS and ZnO-SARS-CoV-2-rN biosensors showed sensitivity to proteins showed higher stability and sensitivity to anti-SARS-CoV-2 antibodies in the range of 0.025–0.5 nM (LOD 0.01 nM) and 0.3–1 nM (LOD 0.3 nM), respectively. Gibbs free energy of interaction between ZnO/SARS-CoV-2-rS and ZnO/SARS-CoV-2-rN bioselective layers with anti-SARS-CoV-2 antibodies showed −35.5 and −21.4 kJ/mol, respectively. Average detection time of biosensor integrated within microfluidic system was 15–20 min. The detection time and pumping speed (50 μl/min) could be reduced to make detection faster. The developed system and ZnO-SARS-CoV-2-rS nanostructures have good potential for detection of anti-SARS-CoV-2 antibodies from patient's probes.
更多
查看译文
关键词
COVID-19 epidemics,Antibodies against SARS-CoV-2 virus proteins,Spike protein (rS),Nucleocapsid protein (rN),Photoluminescence sensor,ZnO tetrapods
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要