Chrome Extension
WeChat Mini Program
Use on ChatGLM

Times, are they a–changing? implantation and follow–up experience with leadless pacemakers (micra) at pisa university hospital

European Heart Journal Supplements(2024)

Cited 0|Views3
No score
Abstract
Abstract Background Leadless pacing represents a pivotal advancement in cardiac stimulation. Eliminating traditional pacing leads, leadless devices offer reduced complications, a bailout strategy for many previously challenging cases and streamlined procedures. Purpose This retrospective study aimed to compare, starting from December 1st 2023, newer implants (within the 3 years preceding Dec 1st 2023) and older implants (>3 years before) in a single–center experience with M–TPS (Micra Transcatheter Pacing System) in terms of safety and efficacy, at baseline and in a short–term follow–up (6 months). Methods A comprehensive analysis was conducted on 195 patients who underwent leadless pacemaker implantation at our Center, and that were followed–up for a minimum of 6 months. The cohort was stratified into two groups: recent (n=73) and less recent implants (n=122). Procedural variables, patient demographics, and clinical outcomes were documented. Post–implantation follow–up data include pacing threshold, fluoroscopy time, and other relevant variables. Results Comparison between the two groups revealed significant differences fluoroscopy time. Newer implants demonstrated a reduced fluoroscopy time [8 (IQR 5–12) vs 10 minutes (IQR 7–14)], suggesting potential advancements in technique. No significant differences were observed in other procedural or electrical parameters. Discussion: The comparison between older and newer leadless pacemaker implants reveals reassuring constancy in most parameters, suggesting the reliability of the M–TPS. The reduced fluoroscopy time aligns with the evolving proficiency of implanters and improved procedural efficiency. The dependable consistency observed across various parameters strengthens the confidence in the M–TPS, reinforcing its status as a reliable and effective solution for pacing. Conclusion The implantation and follow–up experience at our center elucidates very few differences between newer and older implants. This nuanced analysis contributes to the ongoing evolution of leadless pacemaker technology, which heralds a transformative era in cardiac care. With several years of implementation, accumulated follow–up data unveils valuable insights into its sustained effectiveness, guiding clinicians in optimizing patient outcomes and solidifying leadless pacing as a breakthrough in the realm of cardiac rhythm management.
More
Translated text
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined