For the first time, the sequential combination of UVC-LED (276 nm) and photo-Fenton/UVA-LED (376 nm) process has been assessed in continuous flow mode for wastewater reclamation according to the new European Regulation for reuse in agricultural irrigation (EU 2020/741). The results show that it is possible to obtain water quality class B (Escherichia coli <= 100 CFU/100 mL) by UVC-LED irradiation alone, operating the system with a hydraulic residence time (HRT) of 6.5 min and liquid depth of 5 cm in the case of secondary effluents with low Escherichia coli load (8.102-3.1.103 CFU/100 mL). As for high bacteria concentrations (1.2-4.2.104 CFU/100 mL), HRTs longer than 30 min are required. The bacterial load has not influenced decontamination, removing 18 +/- 4 % of microcontaminants. Coupling the UVC (30-min HRT and 5.0 cm liquid depth) and the UVA/photoFenton (60-min and 15-cm liquid depth) systems allows 58 +/- 4 % of real organic microcontaminants to be removed, in addition to achieving water quality class B.