A Mass Sensor Based on 3-DoF Mode Localized BAW Resonators with Enhanced Quality Factor and Resolution

2023 22nd International Conference on Solid-State Sensors, Actuators and Microsystems (Transducers)(2023)

Cited 0|Views3
No score
Abstract
This paper presents a mass sensor based on a 3-degree-of-freedom (DoF) mode localized piezoelectric bulk acoustic wave (BAW) resonator system operating in the contour extensional mode for the first time. It features a quality factor of ~4200 under atmospheric pressure at a resonance frequency of ~6.36 MHz. The mass resolution based on the amplitude ratio output readout is 1.2 pg. Compared with the state of the art, the present device achieved an enhanced performance in terms of both quality factor (~2.37 times higher) and mass resolution (~307 times higher).
More
Translated text
Key words
3-DoF coupled BAW resonators,mass sensor,mode localization,quality factor