Bright luminescent Zn2GeO4:Mn NP/MXene hydrogel-based ECL biosensor for glioblastoma diagnosis

Talanta(2024)

引用 0|浏览0
暂无评分
摘要
In this work, miRNA-10b in the glioblastoma (GBM) tumor tissues has been detected by a novel electrochemiluminescence (ECL) biosensor. Firstly, a new kind of bright luminescent Zn2GeO4:Mn NPs were prepared as ECL nanoprobe, which possessed high fluorescence quantum yield and ECL quantum efficiency. Secondly, Ti3C2 MXene hydrogel (MXG) have been developed as the sensing interface. The MXG retained the inherent biocompatibility and mechanical features of hydrogel. Furthermore, the uniform distribution of metallic Ti3C2 MXene in the hydrogel microstructure provided the good conductivity and multiple binding sites for biomolecules. MXene also can promote the separation of the electrons and holes to accelerate the electron-transfer rate and improve ECL efficiency. Due to these synergistic effects, the screen printed electrode was successfully modified with MXG as sensing platform to enhance the ECL intensity of Zn2GeO4:Mn NP, which greatly improved the detection efficiency and facilitated the high-throughput analysis. Finally, the toehold mediated strand displacement (TMSD) strategy was employed with then biosensor to detect miRNA-10b with the range of 10 fM to 1 nM. The limit of detection was 5 fM. This ECL biosensor has been used to analyze miRNA-10b expression in GBM tumor tissues, which possessed the great potential value for clinical diagnosis.
更多
查看译文
关键词
glioblastoma detection,luminescent Zn2GeO4:Mn NPs,MXene hydrogel,miRNA-10b analysis,ECL sensor