Association between continuous glucose monitoring metrics and clinical outcomes in adults with type 1 diabetes in a real-world setting.

Diabetes research and clinical practice(2024)

引用 0|浏览2
暂无评分
摘要
AIMS:Continuous glucose monitoring (CGM) metrics can assist diabetes management. Consensus statements recommend > 70 % time in range (TIR) and ≤ 36 % glucose coefficient of variation (CV). However, how these targets perform in clinical practice is unknown. This retrospective, longitudinal cohort study analyzed relationships between TIR, CV, glycated hemoglobin (HbA1c), and hypoglycemia in a real-world setting. METHODS:Data of 542 adults with type 1 diabetes who used CGM (January 2014-July 2020) were analyzed. Associations between TIR and HbA1c at the same and subsequent visits, incidence rate ratios (IRRs) for hypoglycemia at different CVs, and number of hypoglycemic events at cross-sections of HbA1c and CV were estimated by regression. RESULTS:TIR was inversely related to HbA1c; for every 10 % increase in TIR, HbA1c was significantly reduced by 0.34 % (4 mmol/mol) and 0.20 % (2 mmol/mol) at the same and subsequent visits, respectively. Level 2 hypoglycemia was significantly reduced at CV < 30 %, 30-33 %, 33.1-36 %, and 36.1-40 %: adjusted IRRs vs CV ≥ 40.1 % of 0.14, 0.28, 0.32, and 0.50, respectively. Hypoglycemic events were reduced at lower CV across HbA1c levels and at higher HbA1c across CV levels. CONCLUSION:This study quantifies HbA1c improvements with increased TIR and hypoglycemia reductions with improved CV in clinical practice.
更多