Prospective Comparison of 68Ga-NeoB and 68Ga-PSMA-R2 PET/MRI in Patients with Biochemically Recurrent Prostate Cancer.

Journal of nuclear medicine : official publication, Society of Nuclear Medicine(2024)

引用 0|浏览5
暂无评分
摘要
Prostate-specific membrane antigen (PSMA) and gastrin-releasing peptide receptors are both overexpressed in prostate cancer (PC) but may provide complementary information.68Ga-PSMA-R2 and 68Ga-NeoB (DOTA-p-aminomethylaniline-diglycolic acid-DPhe-Gln-Trp-Ala-Val-Gly-His-NH-CH[CH2-CH(CH3)2]2) are novel PET radiopharmaceuticals that were developed for theranostic use. In this phase II imaging study, we assessed the feasibility, safety, and diagnostic performance of 68Ga-NeoB and 68Ga-PSMA-R2 PET/MRI for detection of biochemically recurrent PC. Methods: We prospectively enrolled 27 men with suspected biochemically recurrent PC after initial treatment but noncontributory conventional imaging results (negative or equivocal findings on MRI, CT, and/or bone scan). Participants underwent 68Ga-NeoB and 68Ga-PSMA-R2 PET/MRI within 2 wk in noncontrolled order. The SUVmax of putative PC lesions was measured and compared with a composite reference standard (histopathology, follow-up imaging, prostate-specific antigen change). The SUVmax and SUVmean of background organs were measured. Vital signs were recorded before injection of the radiopharmaceuticals and after the scans. Adverse events were recorded up to 72 h after each scan. Results: The prostate-specific antigen level at enrollment was 3.5 ± 3.9 ng/mL (range, 0.3-13.5 ng/mL). 68Ga-NeoB PET/MRI detected 31 lesions in 18 patients (66.7%), whereas 68Ga-PSMA-R2 identified 20 lesions in 15 participants (55.6%). 68Ga-NeoB PET/MRI showed higher sensitivity (85.7% vs. 71.4%), accuracy (88.9% vs. 77.8%), and negative predictive value (66.7% vs. 50.0%) than 68Ga-PSMA-R2, whereas specificity and positive predictive value were equally high (100.0% for both). In 6 patients, 68Ga-NeoB PET/MRI identified 14 lesions that were false-negative on 68Ga-PSMA-R2 PET/MRI. The mean lesion SUVmax was 6.6 ± 3.2 (range, 2.9-13.2) for 68Ga-NeoB and 4.4 ± 1.5 (range, 2.6-8.8) for 68Ga-PSMA-R2 (P = 0.019). Overall lower uptake was noted in tumors and background organs for 68Ga-PSMA-R2. There were no significant changes in vital signs before and after the scans. No adverse events were reported in the 72-h period after scans. Conclusion: 68Ga-NeoB and 68Ga-PSMA-R2 are safe for diagnostic imaging. 68Ga-NeoB PET/MRI showed better diagnostic performance than 68Ga-PSMA-R2. 68Ga-PSMA-R2 showed overall lower uptake, equally in background organs and tumors, and might therefore not be an ideal theranostic compound. Further evaluation in larger cohorts is needed to confirm our preliminary data.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要