Elevated cobalt levels in metal-on-polyethylene knee megaprostheses: a prospective 1-year cohort study of 56 patients with hip and knee megaprostheses

Sarah Stammose Freund, Andrea Pohly Jeppesen Thorn,Ajay Puri,Michael Mork Petersen,Thomas Baad-hansen

ACTA ORTHOPAEDICA(2024)

引用 0|浏览0
暂无评分
摘要
Background and purpose - Concerns have emerged regarding elevated levels of cobalt and chromium in patients with metal -on -metal megaprostheses. This prospective study aims to identify systemic cobalt and chromium levels in metal -on -polyethylene knee and hip megaprostheses and their associations with other factors. Methods - 56 patients underwent knee or hip megaprosthesis surgery at 2 sarcoma centers. Serum cobalt and chromium levels were measured preoperatively and thrice within the first year using inductively coupled plasma mass spectrometry. Results - A statistically significant difference in serum cobalt levels (1.4 ppb; 95% confidence interval [CI] 0.0-3.3) was observed 1 year after knee megaprosthesis surgery compared with preoperative levels. In contrast no difference in chromium levels was observed after 1 year compared with preoperative levels (0.05 ppb; CI 0.0-0.8). An association between younger age, higher eGFR, and increased cobalt levels was observed. No significant correlations were found between ion levels and resection length or the number of modular connections. Conclusion - We found elevated serum ion levels in metal -on -polyethylene knee megaprostheses in contrast to metal -on -polyethylene hip megaprostheses. Furthermore, a positive correlation between cobalt and chromium levels, and between cobalt and eGFR was identified, along with a negative correlation between cobalt and age. This study highlights the importance of monitoring systemic cobalt and chromium levels in patients with megaprostheses.
更多
查看译文
关键词
Chromium,Cobalt,Megaprosthesis
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要