Experimental investigation on tensile behavior of CFRP bolted joints subjected to hydrothermal aging

Hui Chen, Mingjie Li, Zhao Shen, Yitao Zhang, Youhua Zhu,Ye Wu

E-POLYMERS(2024)

Cited 0|Views2
No score
Abstract
With the help of bolted joints to assemble a complex structure, carbon fiber reinforced polymer composite (CFRP) is widely used in various fields. However, stress concentration around holes at the bolted joints leads to a decrease in bearing capacity. Composites often result in mechanical degradation subjected to a complex hydrothermal environment. Therefore, to study the tensile behavior of CFRP bolted joints subjected to hydrothermal aging, the tensile tests are conducted carefully. The influence of aging time and temperature on tensile strength is investigated based on the response history, strain contour, and failure morphology. The failure mechanism is revealed via digital image correlation technology. Finally, the experimental results demonstrate that the bearing capacity of the structure in hydrothermal aging decreases significantly. Compared with the unaged specimens, the peak force of the specimens aged for 6 weeks at 25degree celsius and 65degree celsius is reduced by 22.79% and 35.63%, respectively. Under both the unaged and aged, the same bearing failure is found in the tensile tests of CFRP single-bolt single-lap joints.
More
Translated text
Key words
CFRP,hydrothermal aging,bolted joints,failure mechanism,DIC
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined