Does nurse use of a standardized flowsheet to document communication with advanced providers provide a mechanism to detect pulse oximetry failures? A retrospective study of electronic health record data

International Journal of Nursing Studies(2024)

引用 0|浏览2
暂无评分
摘要
Background Pulse oximetry guides clinical decisions, yet does not uniformly identify hypoxemia. We hypothesized that nursing documentation of notifying providers, facilitated by a standardized flowsheet for documenting communication to providers (physicians, nurse practitioners, and physician assistants), may increase when hypoxemia is present, but undetected by the pulse oximeter, in events termed “occult hypoxemia.” Objective To compare nurse documentation of provider notification in the four hours preceding cases of occult hypoxemia, normal oxygenation, and evident hypoxemia confirmed by an arterial blood gas reading. Methods We conducted a retrospective study using electronic health record data from patients with COVID-19 at five hospitals in a healthcare system with paired SpO2 and SaO2 readings (measurements within 10 min of oxygen saturation levels in arterial blood, SaO2, and by pulse oximetry, SpO2). We applied multivariate logistic regression to assess if having any nursing documentation of provider notification in the four hours prior to a paired reading confirming occult hypoxemia was more likely compared to a paired reading confirming normal oxygen status, adjusting for characteristics significantly associated with nursing documentation. We applied conditional logistic regression to assess if having any nursing documentation of provider notification was more likely in the 4-h window preceding a paired reading compared to the 4-h window 24 h earlier separately for occult hypoxemia, visible hypoxemia, and normal oxygenation. Results There were data from 1910 patients hospitalized with COVID-19 who had 44,972 paired readings and an average of 26.5 (34.5) nursing documentation of provider notification events. The mean age was 63.4 (16.2). Almost half (866/1910, 45.3 %) were White, 701 (36.7 %) were Black, and 239 (12.5 %) were Hispanic. Having any nursing documentation of provider notification was 46 % more common in the 4 h before an occult hypoxemia paired reading compared to a normal oxygen status paired reading (OR 1.46, 95 % CI: 1.28–1.67). Comparing the 4 h immediately before the reading to the 4 h one day preceding the paired reading, there was a higher likelihood of having any nursing documentation of provider notification for both evident (OR 1.45, 95 % CI 1.24–1.68) and occult paired readings (OR 1.26, 95 % CI 1.04–1.53). Conclusion This study finds that nursing documentation of provider notification significantly increases prior to confirmed occult hypoxemia, which has potential in proactively identifying occult hypoxemia and other clinical issues. There is potential value to encouraging standardized documentation of nurse concern, including communication to providers, to facilitate its inclusion in clinical decision-making.
更多
查看译文
关键词
Nurse documentation,COVID-19,Electronic health record data,Pulse oximetry,Nurse/provider communication,Occult hypoxemia
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要