Rapidpulse? cyclic aspiration system for acute ischemic stroke due to large vessel occlusions

Arsida Bajrami,Serdar Geyik,Ozgur Ertugrul,Eren Erdem, Jose Gallego Leon, Giorgio Barbieri, Carlos Dominguez Rodriguez, Jose Carlos Rayon-Aledo, Antonio Sagredo Barra, Fernando S. Sanchez Blanco, Carmen Serna Candel,Francisco Jose Montalverne, Lidemarcks Andrade, Diego Bandeira, Jose Bezerra, Hellen Carm,Henrique Coelho Silva, Alessandra Braga Cruz Guedes de Morais,Adson Freitas de Lucena,Fabricio O. Lima, George Mendes, Felipe A. Rocha,Karlis Kupcs, Helmuts Kidikas,Janis Vetra,Gyula Gal, Anabel Diaz,Raul G. Nogueira

INTERVENTIONAL NEURORADIOLOGY(2024)

引用 0|浏览3
暂无评分
摘要
Background The best strategy to achieve optimal reperfusion outcomes during mechanical thrombectomy remains to be defined. The RapidPulse (TM) Cyclic Aspiration System is a novel technology, delivering high-frequency pulsed vacuum forces to increase the efficiency of aspiration thrombectomy. Methods Prospective, multicenter, open-label, core lab-adjudicated, two-arm study comparing safety and efficacy of a feasibility version of the RapidPulse (TM) system compared with contemporary controls. Primary endpoint was the rate of mTICI >= 2c after first-pass effect (FPE). Additional efficacy endpoints were the rates of mTICI >= 2b after first pass (modified FPE (mFPE)), last pass with study device defined as frontline technical success, and after all passes including rescue therapy. The primary safety endpoints included symptomatic ICH (sICH) within 24 h post-procedure. Results Between February 2022 to December 2022, 80 subjects were consented and enrolled in the study (n = 40 treatment arm, n = 40 control arm). In the intent to treat (ITT) population, mean age was 67.8 +/- 11.5 years; 19 (47.5%) were male. Median NIHSS score was 16 (IQR: 13-22). Median ASPECTS score was 9 (IQR: 8-10). The rate of mTICI >= 2c after first pass was 53.9% in ITT population (60.0% in per-protocol population) versus 38.5% in the corresponding control population. Functional independence (mRS 0-2) at 90 days was achieved in 61.1% (22/36) in the RapidPulse (TM) arm and 52.8% (19/36) in the control arm. In the RapidPulse (TM) arm, no sICH within 24 h and no device-related morbidity or mortality occurred. Conclusion Preliminary data suggests RapidPulse (TM) Aspiration System is highly effective and safe for recanalization of large vessel occlusions.
更多
查看译文
关键词
Stroke,mechanical thrombectomy,cyclic aspiration,LVO
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要