Remote monitoring of atrial fibrillation recurrence using mHealth technology (REMOTE-AF)

EUROPEAN HEART JOURNAL - DIGITAL HEALTH(2024)

引用 0|浏览3
暂无评分
摘要
Aims This proof-of-concept study sought to evaluate changes in heart rate (HR) obtained from a consumer wearable device and compare against implantable loop recorder (ILR)-detected recurrence of atrial fibrillation (AF) and atrial tachycardia (AT) after AF ablation.Methods and results REMOTE-AF (NCT05037136) was a prospectively designed sub-study of the CASA-AF randomized controlled trial (NCT04280042). Participants without a permanent pacemaker had an ILR implanted at their index ablation procedure for longstanding persistent AF. Heart rate and step count were continuously monitored using photoplethysmography (PPG) from a commercially available wrist-worn wearable. Photoplethysmography-recorded HR data were pre-processed with noise filtration and episodes at 1-min interval over 30 min of HR elevations (Z-score = 2) were compared with corresponding ILR data. Thirty-five patients were enrolled, with mean age 70.3 +/- 6.8 years and median follow-up 10 months (interquartile range 8-12 months). Implantable loop recorder analysis revealed 17 out of 35 patients (49%) had recurrence of AF/AT. Compared with ILR recurrence, wearable-derived elevations in HR >= 110 beats per minute had a sensitivity of 95.3%, specificity 54.1%, positive predictive value (PPV) 15.8%, negative predictive value (NPV) 99.2%, and overall accuracy 57.4%. With PPG-recorded HR elevation spikes (non-exercise related), the sensitivity was 87.5%, specificity 62.2%, PPV 39.2%, NPV 92.3%, and overall accuracy 64.0% in the entire patient cohort. In the AF/AT recurrence only group, sensitivity was 87.6%, specificity 68.3%, PPV 53.6%, NPV 93.0%, and overall accuracy 75.0%.Conclusion Consumer wearable devices have the potential to contribute to arrhythmia detection after AF ablation.Study Registration ClinicalTrials.gov Identifier: NCT05037136 https://clinicaltrials.gov/ct2/show/NCT05037136 Graphical Abstract Aims, methods, and findings for REMOTE-AF looking at the detection of AF/AT recurrence using novel composite data from wearables compared with gold standard ILR. AF, atrial fibrillation; AT, atrial tachycardia; HR, heart rate; ILR, implantable loop recorder; LSPAF, long-standing persistent atrial fibrillation; NPV, negative predictive value; PPV, positive predictive value.
更多
查看译文
关键词
Remote monitoring,Wearables,Atrial fibrillation,Digital health,Ablation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要