Simulation and calibration of radiation monitoring of nuclear power plant containment sump waste liquid

Fei Li, Chu -yang Luo, Ying-zi Wen, Sheng Lv,Guo-qiang Zeng,Xiao-hui Liu, Chao Xiong

APPLIED RADIATION AND ISOTOPES(2024)

Cited 0|Views3
No score
Abstract
Waste liquid stored in the containment sumps of nuclear power plants may contain a variety of radionuclides. Real-time monitoring of containment sump waste liquid can ensure that accidents, such as leakage of cooling water, can be avoided. This paper presents the design of a radioactive monitoring system for waste liquid in a containment sump. The detector and the lead-shield in the measurement unit are optimized through Monte Carlo simulations. Experimental verification showed that the background count rate of the measurement chamber in the system was 418.3 cps, and the detection limit of the detection system was 3.01 Bq/L. Distinct gamma-ray characteristic peaks were also observable, demonstrating the system's ability to identify radioactive nuclides in the waste.
More
Translated text
Key words
Waste liquid detection,Nuclide identification,Containment sump