Corrosion of Steel Rebars in Construction Materials with Reinforced Pervious Concrete

INFRASTRUCTURES(2024)

Cited 0|Views3
No score
Abstract
Pervious concrete has great potential for use in many practical applications as a part of urban facilities that can add value through water harvesting and mitigating severe damage from floods. The construction and agricultural industries can take direct advantage of pervious concrete's characteristics when water is a key factor included in projects as part of the useful life of a facility. Pervious concrete also has applications in vertical constructions, fountains, and pedestrian crossings. This work evidences that pervious concrete's corrosion current increases with increasing aggregate size. Also, corrosion is a factor to consider only when steel pieces are immersed, aggravated by the presence of chlorine, but it drains water and does not retain moisture. Steel-reinforced pervious concrete was studied, and the grain size of the inert material and the corrosion process parameters were investigated. The electrochemical frequency modulation technique is proposed as a suitable test for a fast, reproducible assessment which, without damaging reinforced cement structures, particularly pervious concrete, indicates a trend of increasing corrosion current density as the size of the aggregate increases or density diminishes.
More
Translated text
Key words
pervious concrete,aggregate size,corrosion,electrochemical frequency modulation
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined