Bulk Current Injection (BCI) Simulation and Measurement Correlation of an Automotive Battery Cell Voltages and Temperature Monitor IC

Jie Chen,Rajen Murugan, Vishnu Ravinuthula, Willy Bristiel, Taylor Vogt, Chienyu Huang, Bibhu Nayak, Joe Sivaswamy, Harikiran Muniganti,Dipanjan Gope

2023 IEEE Electrical Design of Advanced Packaging and Systems (EDAPS)(2023)

引用 0|浏览0
暂无评分
摘要
Bulk current injection (BCI) testing standard (ISO11452-4) assesses the immunity of a device under test (DUT) and its associated wiring harness to electromagnetically induced disturbance. The ISO11452-4 standard specifies two BCI test methods: the substitution (open-loop) and current monitoring (closed-loop) probe methods. This work develops a system-level modeling methodology to predict an integrated circuit (IC) device immunity performance under closed-loop BCI testing. The coupled transient circuit-to-electromagnetic modeling scheme is validated against direct silicon measurements on an automotive battery cell voltages and temperature monitor IC setup. Overall, a relatively good correlation was seen between simulation and measurement - validating the integrity of the predictive modeling methodology for closed-loop BCI testing.
更多
查看译文
关键词
Automotive,BCI (bulk current injection),BMS (battery management system),Correlation,Closed-Loop,Measurement,Simulation