Methods of measurement for pneumothorax in pediatric patients: a systematic review

Pediatric Surgery International(2024)

引用 0|浏览7
暂无评分
摘要
Accurate measurement of pneumothorax (PTX) size is necessary to guide clinical decision making; however, there is no consensus as to which method should be used in pediatric patients. This systematic review seeks to identify and evaluate the methods used to measure PTX size with CXR in pediatric patients. A systematic review of the literature through 2021 following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) was conducted using the following databases: Ovid/MEDLINE, Scopus, Cochrane Database of Controlled Trials, Cochrane Database of Systematic Reviews, and Google Scholar. Original research articles that included pediatric patients (< 18 years old) and outlined the PTX measurement method were included. 45 studies were identified and grouped by method (Kircher and Swartzel, Rhea, Light, Collins, Other) and societal guideline used. The most used method was Collins (n = 16; 35.6
更多
查看译文
关键词
Pneumothorax,Chest X-ray,Systematic review,Collins method,Measurement