Serum creatinine (SCr) levels are essential for the diagnosis of kidney disease after coronary angiography (CAG). However, the influence of missed post-procedure SCr measurement in this situation is unclear. The present study included 14,127 patients undergoing CAG as part of the Cardiorenal ImprovemeNt registry II. Patients were divided into two groups according to whether a post-procedure SCr was measured within 3 days. The primary endpoint was acute kidney disease (AKD). Logistic regression was used to evaluate the relationship between post-procedure SCr and AKD. Of the 14,127 patients (61.6 +/- 9.8 years, 34.2% females), 55.4% (n = 7822) did not have a post-procedure SCr measurement. The incidence of AKD was higher in the missed post-procedure SCr group (15.7 vs 11.9%; median follow-up 6.54 years). Multivariate logistic regression showed that missed post-procedure SCr measurement was associated with significantly higher risk of AKD (adjusted odds ratio [aOR]: 1.26, 95% CI: 1.10-1.45, P < .001). The results were more significant in patients with normal renal function at baseline (aOR: 1.36, 95% CI: 1.16-1.60, P < .001). In our study, over half of the patients undergoing CAG missed their post-procedure SCr measurement. The missed post-procedure SCr group had a significantly higher risk of developing AKD compared with those with a post-procedure SCr measurement.
更多
查看译文
关键词
serum creatinine,measurement,acute kidney disease,sub-acute kidney injury,coronary angiography