Off-the-Shelf Tibial Cone Sizes May Not Accommodate All Patients' Bone Morphology and May Lead to Cortical Breaches in Revision Total Knee Arthroplasty: A 3D Modeling Study

Wei Shao Tung, Kunsel Kunsel, Gregory R. Roytman,Claire A. Donnelley, Donald Pratola,Steven M. Tommasini,Jenna Bernstein,Daniel H. Wiznia

ARTHROPLASTY TODAY(2024)

引用 0|浏览4
暂无评分
摘要
Background: In revision total knee arthroplasty, tibial cones have demonstrated improved longevity and reduced incidence of aseptic loosening. Several currently available "off -the -shelf" (OTS) cone systems may not have sizes to accommodate all patient bone morphologies. Methods: Computed tomographies from one hundred primary total knee arthroplasty patients and dimensions of 4 OTS cones were obtained. Press -fit stems were positioned in 3D tibia models to fit the diaphyseal trajectory. Cones were positioned around the stem at 1, 6, and 13 mm resections measured from the trough of the medial tibial plateau, simulating proximal tibial cuts and bone loss. Tibias were examined for cortical breaching following modeled cone preparation. Results: Increased rate of breaching was observed as size and depth of the cone increased. In 2/49 (4.1%) male and 19/46 (41.3%) female tibias, cones could not be positioned without breaching. No breaches were found in 22/49 (45.0%) male and 5/46 (10.9%) female tibias. For every 1 centimeter increase in patient height, odds of breaching decreased by 12% (odds ratio: 0.88, confidence interval: 0.84, 0.92). For every size increase in cone width, odds of breaching increased by 34% (odds ratio: 1.34, confidence interval: 1.28, 1.47). Placing cones deeper also increased breaching compared to the 1 mm cut. Conclusions: In revision total knee arthroplasty, smaller OTS or custom tibial cones may be needed to fit a patient's proximal tibial geometry. This is especially true in patients not accommodated by the OTS cone sizes we tested, which impacted shorter patients and/or those with substantial bone loss requiring more tibial resection and deeper cone placement. Use of smaller or custom tibial cones should be considered where indicated. (c) 2024 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons. This is an open access article under the CC BY -NC -ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
更多
查看译文
关键词
3D modeling,Tibial cones,Revision total knee arthroplasty,Total knee arthroplasty,Tibial prosthesis
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要