谷歌浏览器插件
订阅小程序
在清言上使用

The Adherence to an Intraoperative Blood Product Transfusion Algorithm Is Associated With Reduced Blood Product Transfusions in Cardiac Surgical Patients Undergoing Coronary Artery Bypass Grafts and Aortic and/or Valve Replacement Surgery: A Single-Center, Observational Study

Journal of cardiothoracic and vascular anesthesia(2024)

引用 0|浏览10
暂无评分
摘要
Objective: To demonstrate the value of a viscoelastic-based intraoperative transfusion algorithm to reduce non-RBC product administration in adult cardiac surgical patients. Design: A prospective observational study. Setting: At a quaternary academic teaching hospital. Participants: Cardiac surgical patients. Interventions: Viscoelastic-based intraoperative transfusion algorithm. Measurements and Main Results: The study authors compared intraoperative blood product transfusion rates in 184 cardiac surgical patients to 236 historic controls after implementing a viscoelastic-based algorithm. The authors found a non -significant reduction in transfusion of 23.8% for fresh frozen plasma (FFP) units (0.84 +/- 1.4 v 0.64 +/- 1.38; p = ns), 33.4% for platelet units (0.90 +/- 1.39 v 0.60 +/- 131; p = ns), and 15.8% for cryoprecipitate units (0.19 +/- 0.54 v 0.16 +/- 0.50; p = ns). They found a 43.9% reduction in red blood cell (RBC) units transfused (1.98 +/- 2.24 v 0.55 +/- 1.36; p = 0.008). There were no statistically significant differences in time to extubation (8.0 hours (4.0-21.0) v 8.0 (4.0-22.3), reoperation for bleeding (15 [12.3%] v 10 [10.6%]), intensive care unit length of stay (ICU LOS) (51.0 hours [28.0-100.5] v 53.5 [33.3-99.0]) or hospital LOS (9.0 days [6.0-15.0] v 10.0 [7.0-17.0]). Deviation from algorithm adherence was 32.7% (48/147). Packed RBC, FFP, platelets, cryoprecipitate, and cell saver were significantly reduced in the Algorithm Compliant Cohort compared with historic controls, whereas times to extubation, ICU LOS, and hospital LOS did not reach significance. Conclusions: After the implementation of a viscoelastic-based algorithm, patients received fewer packed RBC, FFP, platelets, cryoprecipitate, and cell saver. Algorithm -compliant patients received fewer transfusions; however, reductions in times to extubation, ICU LOS, and hospital LOS were not statistically significant compared with historic controls. (c) 2024 Elsevier Inc. All rights reserved.
更多
查看译文
关键词
Viscoelastic testing,blood product management,Cardiac surgery,Coagulopathy
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要