Improving advanced intraoperative MRI methods during pediatric neurosurgery

Pien E. J. Jellema, Lilli M. Mannsdorfer,Fredy Visser,Alberto De Luca, Cynthia L. E. Smit,Eelco W. Hoving,Kirsten M. van Baarsen,Thomas Lindner, Henk-Jan M. M. Mutsaerts,Jan Willem Dankbaar,Maarten H. Lequin,Jannie P. Wijnen

NMR IN BIOMEDICINE(2024)

引用 0|浏览2
暂无评分
摘要
Advanced intraoperative MR images (ioMRI) acquired during the resection of pediatric brain tumors could offer additional physiological information to preserve healthy tissue. With this work, we aimed to develop a protocol for ioMRI with increased sensitivity for arterial spin labeling (ASL) and diffusion MRI (dMRI), optimized for patient positioning regularly used in the pediatric neurosurgery setting. For ethical reasons, ASL images were acquired in healthy adult subjects that were imaged in the prone and supine position. After this, the ASL cerebral blood flow (CBF) was quantified and compared between both positions. To evaluate the impact of the RF coils setups on image quality, we compared different setups (two vs. four RF coils) by looking at T1-weighted (T1w) signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), as well as undertaking a qualitative evaluation of T1w, T2w, ASL, and dMR images. Mean ASL CBF did not differ between the surgical prone and supine positions in any of the investigated regions of interest or the whole brain. T1w SNR (gray matter: p = 0.016, 34% increase; white matter: p = 0.016, 32% increase) and CNR were higher (p = 0.016) in the four versus two RF coils setups (18.0 +/- 1.8 vs. 13.9 +/- 1.8). Qualitative evaluation of T1w, T2w, ASL, and dMR images resulted in acceptable to good image quality and did not differ statistically significantly between setups. Only the nonweighted diffusion image maps and corticospinal tract reconstructions yielded higher image quality and reduced susceptibility artifacts with four RF coils. Advanced ioMRI metrics were more precise with four RF coils as the standard deviation decreased. Taken together, we have investigated the practical use of advanced ioMRI during pediatric neurosurgery. We conclude that ASL CBF quantification in the surgical prone position is valid and that ASL and dMRI acquisition with two RF coils can be performed adequately for clinical use. With four versus two RF coils, the SNR of the images increases, and the sensitivity to artifacts reduces. We have investigated the practical use of advanced intraoperative MRI during pediatric neurosurgery. We conclude that ASL cerebral blood flow quantification in the surgical prone position is valid and that ASL and diffusion MRI acquisition with two RF coils can be performed adequately for clinical use. When adding two extra RF coils, the signal-to-noise ratio of the advanced ioMR images increases, and the sensitivity to artifacts reduces. image
更多
查看译文
关键词
arterial spin labeling,diffusion MRI,intraoperative,neurosurgery,pediatrics
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要