Test characteristics of point-of-care ultrasonography in patients with acute kidney injury

The Ultrasound Journal(2024)

引用 0|浏览2
暂无评分
摘要
Background Acute kidney injury is a common disorder that is associated with significant morbidity and mortality. Point-of-care ultrasonography (PoCUS) is an imaging modality performed at the bedside and is used to assess for obstructive causes of acute kidney injury. Little is known about the test characteristics of PoCUS in patients with acute kidney injury. Objective Our primary objective was to describe the test characteristics of PoCUS for the detection of hydronephrosis in patients presenting with acute kidney injury at our centre. Our secondary objective was to describe the current rate of use of PoCUS for this indication. Results In total, 7873 patients were identified between June 1, 2019 and April 30, 2021, with 4611 meeting inclusion criteria. Of these, 94 patients (2%) underwent PoCUS, and 65 patients underwent both PoCUS and reference standard, for a total of 124 kidneys included in our diagnostic accuracy analysis. The prevalence of hydronephrosis in our cohort was 33% (95% CI 25–41%). PoCUS had a sensitivity of 85% (95% CI 71–94%) and specificity of 78% (95% CI 68–87%) for the detection of hydronephrosis. Conclusion We describe the test characteristics of PoCUS for the detection of hydronephrosis in a cohort of patients with acute kidney injury. The low uptake of this test presents an opportunity for quality improvement work to increase its use for this indication.
更多
查看译文
关键词
Point-of-care ultrasound,QI,PoCUS,AKI,Diagnostic accuracy