Accuracy and precision of dried urine spot method for the detection of Schistosoma mansoni circulating cathodic antigens in resource-limited settings

Abdallah Zacharia, Clemence Kinabo,Twilumba Makene, Huda Omary, George Ogweno, Faraja Lyamuya,Billy Ngasala

Infectious Diseases of Poverty(2024)

引用 0|浏览0
暂无评分
摘要
Background The World Health Organization recommends the use of Schisto point-of-care circulating cathodic antigens (Schisto POC-CCA) for screening of Schistosoma mansoni as it offers better sensitivity than microscopy. However, there are limitation facing the use of this method including timely availability of the test cassettes. The aim of this study was to determine the reliability of dried urine spot (DUS) method for collection of urine and detection of S. mansoni using Schisto POC-CCA cassettes in a resource-limited settings. Methods A cross-sectional study was conducted between October and November 2022 among 250 primary school children in Sengerema District, northwestern Tanzania. S. mansoni CCA was detected in filter paper-based DUS, liquid urine using DUS Schisto POC-CCA (index), and direct urine Schisto POC-CCA (comparator) methods respectively. S. mansoni eggs in stool were detected using duplicate Kato-Katz (KK) method. The measures of accuracy were computed and compared between the index and comparator methods. The strength of agreement between inter-raters precisions was tested using Cohen’s kappa ( k ). Results This study revealed S. mansoni prevalence rates of 28.8%, 54.0% and 50.8% by duplicate KK, direct urine Schisto POC-CCA and DUS Schisto POC-CCA methods respectively. The mean intensity of infection among infected participants was 86.3 eggs per gram of stool (EPG) ranging from 12.0 EPG to 824.0 EPG. The sensitivity of DUS Schisto POC-CCA and direct urine Schisto POC-CCA was 94.44% (95% CI : 89.15–99.74%) and 97.22% (95% CI : 93.43–100.00%) respectively. The DUS Schisto POC-CCA method had slightly higher specificity (66.85%) than direct urine Schisto POC-CCA method (63.48%). The accuracy of the DUS Schisto POC-CCA was found to be slightly high (74.80%, 95% CI : 68.94–79.06%) compared to that of direct urine Schisto POC-CCA (73.20%, 95% CI : 67.25–78.59%). There was good agreement between two laboratory technologists who performed the DUS Schisto POC-CCA method on similar samples ( k = 0.80, 95% CI : 0.59–0.95). Conclusions The DUS Schisto POC-CCA method had comparable S. mansoni detection accuracy to direct urine Schisto POC-CCA. This suggests that the method could be a potential alternative to direct urine Schisto POC-CCA for screening S. mansoni in resource-limited situations. Graphical Abstract
更多
查看译文
关键词
Accuracy,Point-of-care circulating cathodic antigen,Dried urine spot,Schistosoma mansoni,Sensitivity,Specificity
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要