Numerical Study on Fracture Behavior of Printed Circuit Heat Exchanger Core Based on Elasto-Plastic Phase Field Method

Qianyu Shi, Mingbao Zhang,Qi Li, Zhijian Wang, Pengzhen Ji

JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME(2024)

Cited 0|Views2
No score
Abstract
Printed circuit heat exchanger (PCHE) is a type of compact heat exchanger with high thermal efficiency, more compact, and suitable for high pressure and high temperature conditions. The safety assessment of PCHE is very important, especially for PCHE core. Because PHCE core is different from the PCHE headers which are typical pressure vessel components. However, there is no standard design method to ensure the structural integrity for PCHE core. Some failure modes of PCHE core are studied in recent years, but seldom researches have been conducted concerning the fracture behavior of PCHE core. In addition, the phase field method for fracture has developed rapidly in recent years with its advantages in predicting crack initiation, bifurcation, and merging. In this work, the fracture behavior of PCHE core with and without defects is investigated based on elasto-plastic phase field method. The model parameter of Ni-based Alloy for elasto-plastic phase field method is first calibrated by comparing the numerical results with tensile test data of diffusion-bonded PHCE core specimen. Then, the influence of loading directions, defect locations, and defect sizes on the fracture behavior of PCHE core with semicircular and semicircular-rectangular channels are analyzed. Some conclusions are discussed.
More
Translated text
Key words
fracture behavior,phase field method,PCHE,fracture simulation,numerical study
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined