Stimulated Secondary Emission of Single Photon Avalanche Diodes

Kurtis Raymond,Fabrice Retière, Harry Lewis,Andrea Capra, Duncan McCarthy,Austin de St Croix,Giacomo Gallina, Joe McLaughlin, Juliette Martin,Nicolas Massacret, Paolo Agnes, Ryan Underwood, Seraphim Koulosousas,Peter Margetak

arxiv(2024)

引用 0|浏览2
暂无评分
摘要
Large-area next-generation physics experiments rely on using Silicon Photo-Multiplier (SiPM) devices to detect single photons, which trigger charge avalanches. The noise mechanism of external cross-talk occurs when secondary photons produced during a charge avalanche escape from an SiPM and trigger other devices within a detector system. This work presents measured spectra of the secondary photons emitted from the Hamamatsu VUV4 and Fondazione Bruno Kessler VUV-HD3 SiPMs stimulated by laser light, near operational voltages. The work describes the Microscope for the Injection and Emission of Light (MIEL) setup, which is an experimental apparatus constructed for this purpose. Measurements have been performed at a range of over-voltage values and temperatures from 86 K to 293 K. The number of photons produced per avalanche at the source are calculated from the measured spectra and determined to be 40±9 and 61±11 photons produced per avalanche for the VUV4 and VUV-HD3 respectively at 4 volts over-voltage. No significant temperature dependence is observed within the measurement uncertainties. The overall number of photons emitted per avalanche from each SiPM device are also reported.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络