Equivalent uniform RBE-weighted dose in eye plaque brachytherapy

MEDICAL PHYSICS(2024)

引用 0|浏览0
暂无评分
摘要
BackgroundBrachytherapy for ocular melanoma is based on the application of eye plaques with different spatial dose nonuniformity, time-dependent dose rates and relative biological effectiveness (RBE). PurposeWe propose a parameter called the equivalent uniform RBE-weighted dose (EUDRBE) that can be used for quantitative characterization of integrated cell survival in radiotherapy modalities with the variable RBE, dose nonuniformity and dose rate. The EUDRBE is applied to brachytherapy with 125I eye plaques designed by the Collaborative Ocular Melanoma Study (COMS). MethodsThe EUDRBE is defined as the uniform dose distribution with RBE = 1 that causes equal cell survival for a given nonuniform dose distribution with the variable RBE > 1. The EUDRBE can be used for comparison of cell survival for nonuniform dose distributions with different RBE, because they are compared to the reference dose with RBE = 1. The EUDRBE is applied to brachytherapy with 125I COMS eye plaques that are characterized by a steep dose gradient in tumor base-apex direction, protracted irradiation during time intervals of 3-8 days, and variable dose-rate dependent RBE with a maximum of about 1.4. The simulations are based on dose of 85 Gy prescribed to the farthest intraocular extent of the tumor (tumor apex). To compute the EUDRBE in eye plaque brachytherapy and correct for protracted irradiation, the distributions of physical dose have been converted to non-uniform distributions of biologically effective dose (BED) to include the biological effects of sublethal cellular repair, Our radiobiological analysis considers the combined effects of different time-dependent dose rates, spatial dose non-uniformity, dose fractionation and different RBE and can be used to derive optimized dose regimens brachytherapy. ResultsOur simulations show that the EUDRBE increases with the prescription depths and the maximum increase may achieve 6% for the tumor height of 12 mm. This effect stems from a steep dose gradient within the tumor that increases with the prescription depth. The simulations also show that the EUDRBE increase may achieve 12% with increasing the dose rate when implant duration decreases. The combined effect of dose nonuniformity and dose rate may change the EUDRBE up to 18% for the same dose prescription of 85 Gy to tumor apex. The absolute dose range of 48-61 Gy (RBE) for the EUDRBE computed using 4 or 5 fractions is comparable to the dose prescriptions used in stereotactic body radiation therapy (SBRT) with megavoltage X-rays (RBE = 1) for different cancers. The tumor control probabilities in SBRT and eye plaque brachytherapy are very similar at the level of 80% or higher that support the hypothesis that the selected approximations for the EUDRBE are valid. ConclusionsThe computed range of the EUDRBE in 125I COMS eye plaque brachytherapy suggests that the selected models and hypotheses are acceptable. The EUDRBE can be useful for analysis of treatment outcomes and comparison of different dose regimens in eye plaque brachytherapy.
更多
查看译文
关键词
BED,EUD,eye plaque brachytherapy,LQ model,RBE
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要