Does plate position influence the outcome in midshaft clavicular fractures? A multicenter analysis

European Journal of Trauma and Emergency Surgery(2024)

引用 0|浏览5
暂无评分
摘要
Purpose To date, it remains unclear whether superior or anterior plating is the best option for treating midshaft clavicular fractures. The aim of this study was to compare both techniques with regard to the incidence of implant removal due to implant irritation, risk of complications, time to union, and function. Methods In this retrospective cohort study, all midshaft clavicular fractures treated operatively between 2017 and 2020 in two hospitals in Switzerland were analyzed. The participating hospitals differed with regard to their standard practice; one offered superior plating only, while the other predominantly employed an anterior plate. The primary outcome was the incidence of implant removal for irritation. Secondary outcomes were time to union, complications, re-interventions, and range of motion during the follow-up period of at least 6 months. Results In total, 168 patients were included in the study of which 81 (48%) received anterior plating and 87 (52%) superior plating. The overall mean age was 45 years (SD 16). There was no significant difference between anterior and superior plating with regard to implant removal (58.5% versus 57.1%, p = 0.887), infection (5.7% versus 1.8%, p = 0.071), and time to union (median 48 weeks versus 52 weeks, p = 0.643). Data on range of motion were available in 71 patients. There was no significant difference in anteflexion (median 180 degrees anterior versus 180 degrees superior) and abduction (median 180 degrees anterior versus 180 degrees superior) between the two groups. Conclusion This retrospective cohort study did not find sufficient evidence to recommend one implant position over the other for midshaft clavicular fractures with regard to removal due to irritation. Time to union was similar and Infections were equally rare in both groups. Notably, a considerable number of patients in both groups had their implants removed due to irritation. Larger prospective studies are needed to determine how much plate position contributes to the occurrence of irritation and whether other patient or implant-related factors might play a role. Until this is clarified, implant position should be based on surgeons preference and experience.
更多
查看译文
关键词
Midshaft clavicular fracture,Clavicle fracture,Plate position,Hardware irritation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要