Chrome Extension
WeChat Mini Program
Use on ChatGLM

Pancreatic SABR using peritumoral fiducials, triggered imaging and breath-hold

PATHOLOGY & ONCOLOGY RESEARCH(2023)

Cited 0|Views5
No score
Abstract
Background: We aim to present our linear accelerator-based workflow for pancreatic stereotactic ablative radiotherapy (SABR) in order to address the following issues: intrafractional organ motion management, Cone Beam CT (CBCT) image quality, residual errors with dosimetric consequences, treatment time, and clinical results.Methods: Between 2016 and 2021, 14 patients with locally advanced pancreatic cancer were treated with induction chemotherapy and SABR using volumetric modulated arc therapy (VMAT). Internal target volume (ITV) concept (5), phase-gated (4), or breath hold (5) techniques were used. Treatment was verified by CBCT before and after irradiation, while tumor motion was monitored and controlled by kV triggered imaging and beam hold using peritumoral surgical clips. Beam interruptions and treatment time were recorded. The CBCT image quality was scored and supplemented by an agreement analysis (Krippendorff's-alpha) of breath-hold CBCT images to determine the position of OARs relative to the planning risk volumes (PRV). Residual errors and their dosimetry impact were also calculated. Progression free (PFS) and overall survival (OS) were assessed by the Kaplan-Meier analysis with acute and late toxicity reporting (CTCAEv4).Results: On average, beams were interrupted once (range: 0-3) per treatment session on triggered imaging. The total median treatment time was 16.7 +/- 10.8 min, significantly less for breath-hold vs. phase-gated sessions (18.8 +/- 6.2 vs. 26.5 +/- 13.4, p < 0.001). The best image quality was achieved by breath hold CBCT. The Krippendorff's-alpha test showed a strong agreement among five radiation therapists (mean K-alpha value: 0.8 (97.5%). The mean residual errors were <0.2 cm in each direction resulting in an average difference of <2% in dosimetry for OAR and target volume. Two patients received offline adaptation. The median OS/PFS after induction chemotherapy and SABR was 20/12 months and 15/8 months. No Gr. >= 2 acute/late RT-related toxicity was noted.Conclusion: Linear accelerator based pancreatic SABR with the combination of CBCT and triggered imaging + beam hold is feasible. Peritumoral fiducials improve utility while breath-hold CBCT provides the best image quality at a reasonable treatment time with offline adaptation possibilities. In well-selected cases, it can be an effective alternative in clinics where CBCT/MRI-guided online adaptive workflow is not available.
More
Translated text
Key words
motion control,pancreatic cancer,triggered imaging,stereotactic ablative radiotherapy,deep inspiration breath hold
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined