Conventional biventricular pacing is still preferred to conduction system pacing for atrioventricular block in patients with reduced ejection fraction and narrow QRS

EUROPACE(2023)

引用 0|浏览4
暂无评分
摘要
It is well established that right ventricular pacing is detrimental in patients with reduced cardiac function who require ventricular pacing (VP), and alternatives nowadays are comprised of biventricular pacing (BiVP) and conduction system pacing (CSP). The latter modality is of particular interest in patients with a narrow baseline QRS as it completely avoids, or minimizes, ventricular desynchronization associated with VP. In this article, experts debate whether BiVP or CSP should be used to treat these patients. Graphical abstract
更多
查看译文
关键词
Cardiac pacing,Biventricular pacing,Atrioventricular block,Narrow QRS,Heart failure,Conduction system pacing,His bundle branch pacing,Left bundle branch area pacing,Cardiac resynchronization therapy