Chrome Extension
WeChat Mini Program
Use on ChatGLM

In-Hospital and 1-Year Clinical Results from the French Registry Using Polymer-Free Sirolimus-Eluting Stents in Acute Coronary Syndrome and Stable Coronary Artery Disease

Quentin Landolff, Marine Quillot,Fabien Picard,Patrick Henry,Georgios Sideris,Olivier Bizeau,Christophe Piot,Bernard Jouve,Jerome Rischner, Mourad Mejri, Claude Charmasson, Raphael Lasserre, Herve Pouliquen, Thierry Joseph,Jacques Monsegu,Bernard Karsenty, Victoria Martin Yuste, Nicolas Richet, Guy Lapeyre, Fabrizio Beverelli,Farzin Beygui,Rene Koning

Journal of Interventional Cardiology(2023)

Cited 0|Views6
No score
Abstract
Objectives. The aim of this postmarket clinical study was to assess the safety and efficacy of the latest generation polymer-free sirolimus-eluting stents (PF-SES) in an all-comers population comparing outcomes in stable coronary artery disease (CAD) versus acute coronary syndrome (ACS) in France. Background. The efficacy and safety of the first-generation PF-SES have already been demonstrated by randomized controlled trials and "all-comers" observational studies. Methods. For this all-comers observational, prospective, multicenter study, 1456 patients were recruited in 22 French centers. The primary endpoint was target lesion revascularization (TLR) rate at 12 months and secondary endpoints included major adverse cardiac events (MACE) and bleeding. Results. 895 patients had stable CAD and 561 had ACS. At 12 months, 2% of patients had a TLR, with similar rates between stable CAD and ACS (1.9% vs 2.2%, p = 0.7). The overall MACE rate was 5.2% with an expected higher rate in patients with ACS as compared to those with stable CAD (7.3% vs 3.9%, p = 0.007). The overall bleeding event rate was 4.5%, with similar rates in stable CAD as compared to ACS patients (3.8% vs 5.6%, p = 0.3). Dual antiplatelet therapy (DAPT) interruptions prior to the recommended duration occurred in 41.7% of patients with no increase in MACE rates as compared to patients who did not prematurely interrupt DAPT (3.9% vs 6.1%, p = 0.073). Conclusions. The latest generation PF-SES is associated with low clinical event rates in these all-comers patients. There was a high rate of prematurely terminated DAPT, without any effect on MACE at 12 months. This trial is registered with NCT03809715.
More
Translated text
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined