Effects of the low-speed continuous infusion catheter technique on double-lumen central venous catheters: A randomized controlled trial

Mian Zhou, Shan Dong,Jinghui Zhang,Yuping Liu, Liuliu Zhang, Junxia Xu, Ying Yang, Yulan He, Kaiping Wu, Yuan Yuan,Wenqin Lin, Wenxia Bian,Juan Li,Chunli Chen,Youhua Xue,Tingting Tao, Yubiao Kang, Lulu Sun,Ling Yuan,Cuirong Xu

INTERNATIONAL JOURNAL OF NURSING STUDIES(2024)

Cited 0|Views11
No score
Abstract
Background: Central venous catheters are widely used in clinical practice, and the incidence of central venous catheter occlusion is between 25 % and 38 %. The turbulence caused by the pulsatile flushing technique is harmful to the vascular endothelium and may lead to phlebitis. The low-speed continuous infusion catheter technique is a new type of continuous infusion that ensures that the catheter is always in a keep-vein-open state by continuous low-speed flushing; hence, avoiding the problem of catheter occlusion. Objective: To investigate the effectiveness of the low-speed continuous infusion catheter technique and the routine care of double-lumen central venous catheters. Design: This was a prospective, randomized, controlled, open-label trial. Setting: Patients were recruited from 14 medical institutions in China between February and June 2023. Participants: In total, 251 patients were recruited, with 125 in the intervention group and 126 in the control group. Methods: Patients who used double-lumen central venous catheters for infusion treatment were selected, and those who met the sampling criteria were randomly divided into intervention and control groups using the random envelope method. The intervention group used the low-speed continuous infusion catheter technique to maintain catheter patency, whereas the control group used routine care with a trial period of 7 days. The primary outcome was the occlusion rate. The secondary outcomes included nursing satisfaction and complication rates of the two groups. Results: After 7 days, the rate of catheter occlusion was 28.0 % (35/125, 95 % confidence interval (CI):0.203, 0.367) in the intervention group and 53.97 % (68/126, 95 % CI: 0.449-0.629) in the control group, with a statistically significant difference (chi(2) = 17.488, p < 0.001); at 3 days of intervention, the rate of catheter blockage was 8.0 % (10/125, 95 % CI: 0.039-0.142) in the intervention group and 23.8 % (30/126, 0.167-0.322) in the control group, with a statistically significant difference (chi(2) = 11.707, p < 0.001). Nurse satisfaction was significantly higher in the intervention group (115/125, 92.0 %, 95 % CI: 0.858-0.961) than in the control group (104/126, 82.54 %, 95 % CI: 0.748-0.887) (chi(2) = 5.049, p = 0.025). There were no statistically significant complication rates in either group (p = 0.622). Conclusion: The low-speed continuous infusion catheter technique helps maintain catheter patency, improves nurse satisfaction, and provides a high level of safety. Registration: Chinese Clinical Trial Registry (ChiCTR2200064007, www.chictr.org.cn). The first recruitment was conducted in February. https://www.chictr.org.cn/showproj.html?proj=177311. (c) 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
More
Translated text
Key words
Central venous catheter,Continuous flow,Flushing,Pulsatile flow,Nursing care,Randomized controlled trial
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined