Hemostasis after transradial coronary intervention by rotary compression device with sterile gauze is associated with more adverse events: a retrospective study

Coronary artery disease(2024)

Cited 0|Views12
No score
Abstract
ObjectiveWe investigated the relationship between using a rotary compression device (RCD) with or without sterile gauze and adverse events in transradial access (TRA) for coronary intervention.MethodsIn this study involving 933 patients at Yueyang Hospital, we recorded TRA-related adverse events, such as bleeding, forearm hematoma, swollen palms, radial artery occlusion (RAO) and others. Logistic regression was applied to assess the association.ResultsOf the 933 patients (66.7% males, average age 67.8 years), 511 used RCD with sterile gauze, whereas 422 used RCD without sterile gauze. The most common adverse events were radial artery hemorrhage (7.4%), hand swelling (4.8%) and RAO (4.6%). Logistic regression analysis revealed that the use of RCD with sterile gauze was associated with a higher prevalence of adverse events [odds ratio (OR), 1.74; 95% confidence interval (CI), 1.22-2.49), even with the adjustment of potential confounders (OR, 1.71; 95% CI, 1.19-2.45). Moreover, patients who used RCD with sterile gauze exhibited an increased risk of radial artery hemorrhage (OR, 1.83; 95% CI, 1.07-3.12), swelling of the hand (OR, 1.96; 95% CI, 1.02-3.75) and RAO (OR, 3.17; 95% CI, 1.49-6.72).Conclusions:The use of RCD with sterile gauze in TRA is associated with a higher incidence of adverse events.
More
Translated text
Key words
complication,radial artery occlusion,rotary compression device,sterile gauze,transradial coronary intervention
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined