谷歌浏览器插件
订阅小程序
在清言上使用

Influence of image preprocessing on the segmentation-based reproducibility of radiomic features: in vivo experiments on discretization and resampling parameters

Burak Kocak,Sabahattin Yuzkan,Samet Mutlu,Mehmet Karagulle, Ahmet Kala, Mehmet Kadioglu,Sila Solak, Seyma Sunman, Zisan Hayriye, Ali Kursad Ganiyusufoglu

DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY(2024)

引用 0|浏览5
暂无评分
摘要
PURPOSE To systematically investigate the impact of image preprocessing parameters on the segmentation-based reproducibility of magnetic resonance imaging (MRI) radiomic features. METHODS The MRI scans of 50 patients were included from the multi-institutional Brain Tumor Segmentation 2021 public glioma dataset. Whole tumor volumes were manually segmented by two independent readers, with the participation of eight readers. Radiomic features were extracted from two sequences: T2-weighted (T2) and contrast-enhanced T1-weighted (T1ce). Two methods were considered for discretization: bin count (i.e., relative discretization) and bin width (i.e., absolute discretization). Ten discretization (five for each method) and five resampling parameters were varied while other parameters were fixed. The intraclass correlation coefficient (ICC) was used for reliability analysis based on two commonly used cut -off values (0.75 and 0.90). RESULTS Image preprocessing parameters had a significant impact on the segmentation-based reproducibility of radiomic features. The bin width method yielded more reproducible features than the bin count method. In discretization experiments using the bin width on both sequences, according to the ICC cut -off values of 0.75 and 0.90, the rate of reproducible features ranged from 70% to 84% and from 35% to 57%, respectively, with an increasing percentage trend as parameter values decreased (from 84 to 5 for T2; 100 to 6 for T1ce). In the resampling experiments, these ranged from 53% to 74% and from 10% to 20%, respectively, with an increasing percentage trend from lower to higher parameter values (physical voxel size; from 1 x 1 x 1 to 2 x 2 x 2 mm 3 ). CONCLUSION The segmentation-based reproducibility of radiomic features appears to be substantially influenced by discretization and resampling parameters. Our findings indicate that the bin width method should be used for discretization and lower bin width and higher resampling values should be used to allow more reproducible features.
更多
查看译文
关键词
Reproducibility,preprocessing,radiomics,texture analysis,biomarker
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要