Appropriateness of implantable cardioverter-defibrillator device implants in the United States.

Heart rhythm(2023)

引用 0|浏览6
暂无评分
摘要
BACKGROUND:The appropriate use criteria (AUCs) are a diverse group of indications aimed to better evaluate the benefits of implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy. OBJECTIVE:The purpose of this study was to quantify the proportion of ICD and cardiac resynchronization therapy with defibrillator (CRT-D) implants as appropriate, may be appropriate (MA), or rarely appropriate (RA) on the basis of the AUC guidelines. METHODS:This is a multicenter retrospective study of patients within the National Cardiovascular Data Registry undergoing ICD implantation between April 2018 and March 2019 at >1500 US hospitals. The appropriateness of ICD implants was adjudicated using the AUC. RESULTS:Of 309,318 ICDs, 241,438 were primary prevention implants (78.1%) and 67,880 secondary prevention implants (21.9%); 243,532 (79%) were mappable to the AUC. For primary prevention, 185,431 ICDs (96.4%) were appropriate, 5660 (2.9%) MA, and 1205 (0.6%) RA. For secondary prevention, 47,498 ICDs (92.7%) were appropriate, 2581 (5%) MA, and 1157 (2.3%) RA. A significant number of RA devices were implanted in patients with New York Heart Association class IV heart failure who were ineligible for advanced therapies (53.9%) and those with myocardial infarction within 40 days (18.1%). The appropriateness of the pacing lead was more variable, with 48,470 dual-chamber ICD implants (62%) being classified as appropriate, 29,209 (37.4%) MA, and 448 (0.6%) RA. Among CRT-D implants, 63,848 (82.2%) were appropriate, 9900 (12.7%) MA, and 3940 (5.1%) RA for left ventricular pacing. A total of 99,754 implants were deemed appropriate but excluded from Centers for Medicare & Medicaid Services National Coverage Determination. More than 92% of hospitals had an RA implant rate of <4%. CONCLUSION:In this large national registry, 95% of mappable ICD and CRT-D implants were considered appropriate, with <2% of RA implants. Nearly 100,000 appropriate implants are excluded by Centers for Medicare & Medicaid Services National Coverage Determination.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要