High-sensitivity phase imaging eddy current magneto-optical system for carbon fiber reinforced polymers detection

Journal of Electronic Science and Technology(2023)

引用 0|浏览2
暂无评分
摘要
This paper proposed a high-sensitivity phase imaging eddy current magneto-optical(PI-ECMO)system for carbon fiber reinforced polymer(CFRP)defect detection.In contrast to other eddy current-based detection systems,the proposed system employs a fixed position excitation coil while enabling the detection point to move within the detection region.This configuration effectively mitigates the interference caused by the lift-off effect,which is commonly observed in systems with moving excitation coils.Correspondingly,the relationship between the defect characteristics(orientation and position)and the surface vertical magnetic field distribution(amplitude and phase)is studied in detail by theoretical analysis and numerical simulations.Experiments conducted on woven CFRP plates demonstrate that the designed PI-ECMO system is capable of effectively detecting both surface and internal cracks,as well as impact defects.The excitation current is significantly reduced compared with traditional eddy current magneto-optical(ECMO)systems.
更多
查看译文
关键词
Carbon fiber reinforced polymers,Defect detection,Eddy current magneto-optical,Nondestructive testing,Phase imaging