Use of a wearable patch sensor for continuous activity and posture tracking to assess risk of early infection after transcatheter aortic valve replacement

European Heart Journal(2023)

Cited 0|Views4
No score
Abstract
Abstract Background Early infections after transcatheter aortic valve replacement (TAVR) represent one of the most common risk factors for non-cardiac 30-day mortality. Several wearable devices have been developed to measure vital signs and physical activity in real time while allowing full mobilization of the patient. However, their use has not been evaluated in a clinical setting with patients undergoing TAVR yet. Purpose We aimed to evaluate the feasibility of wearable patch sensors in assessing vital signs and daily activity before and after TAVR to predict an increased risk of early infections following TAVR. Methods Patients at high risk for infection undergoing transfemoral TAVR under local anesthesia were enrolled between September 2022 and January 2023. Postprocedural early infections were assessed, defined as C-reactive protein rise within 5 days after the procedure inducing antibiotic treatment. Vital signs (heart rate, respiratory rate, single-lead ECG) and activity (steps, posture) were monitored by a wearable patch sensor two days before (pre-TAVR) and two days after TAVR (post-TAVR). Results 54 patients completed 5 days of in-hospital monitoring with wearable patch sensors. The mean age was 80.3+5.2 years, 31 patients (57.4%) were male. Early infections occurred in 8 of 54 (14.8%) high-risk patients, of whom one was a urinary tract, one a pulmonary, and two access site-related etiology. Four infections remained with unknown focus. Respiratory rate was generally higher in patients developing an early infection after TAVR in both time periods, before (early infection 22±3 vs. no infection 18±2 bpm; p=0.001) and after TAVR (early infection 24±3 vs. no infection 19±3 bpm; p<0.001). Early infections were more prevalent in patients who showed less activity in the two days before TAVR regarding lower step count (early infection 242±360 vs. no infection 515±566; p=0.048) and high percentage of lying position during the whole day (early infection 89±12% vs. no infection 64±23%; p=0.071). Two days after TAVR, there were no significant differences in activity levels between both cohorts. Physical activity was reduced in both groups compared to the two days before TAVR, resulting in a reduced number of steps (pre-TAVR 473±546 vs. post-TAVR 267±434; p=0.039) and more daytime spent in lying position (pre-TAVR 57±19% vs. post-TAVR 73±24%; p<0.0001). Conclusion Wearable patch sensors are feasible to track vital signs and physical activity during hospital stay with promising opportunity for improving clinical management in TAVR patients. Early infections after TAVR are associated with decreased preprocedural mobility in high-risk patients. Therefore, these patients may be prematurely detected using wireless respiratory rate monitoring and infections prevented by intensified physiotherapy.
More
Translated text
Key words
wearable patch sensor,transcatheter aortic valve,transcatheter aortic valve replacement,aortic valve replacement,posture tracking
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined