CT oesophageal hiatal surface area measurements: An objective and sensitive means of hiatal hernia detection

Daniel L. Chan, Brenda W. Huang, Jim Yip, Manish Chug,Jim Iliopoulos,Hennessy Annemarie,Michael Talbot

Surgery Open Digestive Advance(2023)

引用 1|浏览5
暂无评分
摘要
•A retrospective analysis of 287 consecutive patients (2005–2016) who underwent laparoscopic hiatal hernia (HH) repair. Preoperative investigations and CT hiatal surface area (HSA) measurements were evaluated.•Overall, sensitivity for preoperative HH detection was 75.3% (n = 259) for endoscopy, 77.4% (n = 106) for barium swallow, 70.9% (n = 110) for HRM and 80.4% (n = 56) for standard CT reporting. Preoperative sensitivity for CT HSA was 94.6% (n = 37).•Mean CT HSA was significantly higher in the HH group compared to a 1:1 matched control group (8.7cm2 vs 2.2cm2, p < 0.01).•The accuracy of independent radiologist and surgeon observers was the same at 94.6%, with an intra-class correlation coefficient of 1.00 (p < 0.01) demonstrating excellent reliability.
更多
查看译文
关键词
hiatal hernia detection,hiatal surface area measurements
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要