On the Separation of Yttrium-90 from High-Level Liquid Waste: Purification to Clinical-Grade Radiochemical Precursor, Clinical Translation in Formulation of90Y-DOTATATE Patient Dose

Cancer Biotherapy and Radiopharmaceuticals(2021)

Cited 3|Views0
No score
Abstract
Introduction: The quality control parameters of in-house-produced 90Y-Acetate from high-level liquid waste (HLLW) using supported liquid membrane (SLM) technology were validated and compared with the pharmacopeia standard. The radiolabeling of DOTATATE yielding 90Y-DOTATATE in acceptable radiochemical purity (RCP), with expected pharmacological behavior in in vivo models, establish the quality of 90Y-Acetate. Clinical translation of 90Y-Acetate in formulation of 90Y-DOTATATE adds support toward its use as clinical-grade radiochemical. Methods: Quality control parameters of 90Y-Acetate, namely radionuclide purity (RNP), were evaluated using β- spectrometry, γ-spectroscopy, and liquid scintillation counting. RCP and metallic impurities were established using high-performance liquid chromatography and inductively coupled plasma optical emission spectrometry, respectively. The suitability of 90Y-Acetate as an active pharmaceutical ingredient radiochemical was ascertained by radiolabeling with DOTATATE. In vivo biodistribution of 90Y-DOTATATE was carried out in nude mice bearing AR42J xenografted tumor. Clinical efficacy of 90Y-DOTATATE was established after using in patients with large-volume neuroendocrine tumors (NET). Bremsstrahlung imaging was carried out in dual-head gamma camera with a wide energy window setting (100-250 keV). Results: In-house-produced 90Y-Acetate was clear, colorless, and radioactive concentration (RAC) in the range of 40-50 mCi/mL. RCP was >98%. 90Sr content was <0.85 μCi/Ci of 90Y. Gross λ content was <0.8 nCi/Ci of 90Y and no γ peak was observed. Fe3+, Cu2+, Zn2+, Cd2+, and Pb2+ contents were <1.7 μg/Ci. The radiolabeling yield (RLY) of 90Y-DOTATATE was >94%, RCP was >98%. The in vitro stability of 90Y-DOTATATE was up to 72 h postradiolabeling, upon storage at -20°C. Post-therapy (24 h) Bremsstrahlung image of patients with large NET exhibit complete localization of 90Y-DOTATATE in tumor region. Conclusions: This study demonstrates that the in-house-produced 90Y-Acetate from HLLW can be used for the formulation of various therapeutic 90Y-based radiopharmaceuticals. Since 90Y is an imported radiochemical precursor available at a high cost in India, this study which demonstrates the suitability of indigenously sourced 90Y, ideally exemplifies the recovery of "wealth from waste." The Clinical Trial Registration number: (P17/FEB/2019).
More
Translated text
Key words
purification,high-level,clinical-grade,y-dotatate
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined