Chrome Extension
WeChat Mini Program
Use on ChatGLM

Магнитно-резонансная панангиография аорты, коронарных и внутренних грудных артерий в вычислительном анатомическом планировании оптимального малоинвазивного маммарокоронарного шунтирования

В. Ю. Усов, И. М. Скурихин,П. И. Лукьяненок,Ю. Ю. Вечерский, Т. А. Бахметьева,Т. А. Шелковникова, Ю. П. Усов,Alexander Shelupanov, О. Беличенко

Медицинская визуализация(2016)

Cited 0|Views0
No score
Abstract
Backgrond . Efficiency of low-invasive angiosurgical revascularisation techniques essentially depends on precise and individualised anatomic localization of arteries involved to the procedure. In particular when carrying out the lowinvasive mammarocoronary bypass surgery this means the optimal selection of intercostal anatomic approach adjusted to real position of internal thoracic and coronary arteries. Nevertheless the real possibilities of use of the MRI simultaneously with MR-angiography (MRA) for 3D pre-surgical design and personalization of surgical technique in every personal case according to real anatomic relation of coronary and internal thoracic arteries remain underemployed. Both the feasibilities and long-term results of individual virtual design of mammarocoronary bypass surgery based on routine chest MRI and MRA data are not yet studied, and the real efficiency of such approach remains unclear. Aim: comprised first the development of a technique of 3D virtual anatomic design of mammarocoronary bypass surgery basing on the data of simultaneous ssfp-MRA imaging of coronary and internal mammary arteries and on set of chest MRI tomographic images, in order to improve the results of mammarocoronary mini-invasive transthoracic technique of bypass; and second, the technique was briefly evaluated from the one-year follow-up clinical results. Material and Methods . The patient’s material comprised overall 23 persons who were assigned to two groups – first the fourteen (61%) patients of the main group, in whom the low-invasive mammarocoronary bypass surgeru was carried out; and the nine patients (39%) of the comparison group, recruited from earlier cases, in whom the surgical intervention was performed without evaluation of chest MR-angiographic data. The MRI and MR-angiography, later employed for threedimensional quantification of inter-position of heart surface, of anterior descendent coronary artery, of internal mammary artery, of bone, chet wall muscular and catilage structures, comprised chest breath- and ECG-synchronized MRI with detailed imaging of anterior chest wall, intercostal spaces and internal mammary artery, imaging of the heart itself using two- and four-chamber long-axis positions, and pan-angiography of chest aorta and major arteries, including coronary arteries and internal thoracic arteries. The slices were 4–7 mm thin, acquired to matrix 256 × 256 or 256 × 392 voxels, with field of view as big as 30 × 40 cm. From the 3D model of thoracic and coronary arteries the optimal surgical technique was designed in every clinical case basing on critrion of minimal distance between internal thoracic artey and antrior descending artery as rationale for selection of intercostal level for endoscope introduction and location of aretrio-arterial anastomosis between internal thoracic and coronary arteries. Results. The possibilities of individual anatomic adjustment based on MR-angiography of thoracic arteries were evaluated in fourteen patients in whom the mammarocoronary shunts were carried out basing on MRA data, delivering no any occlusion of the shunt during 12.5 ± 2.2 mnths follow- up. As a control group nine patients who underwent mammarocoronay bypass surgery without pre-operational MRI anatomic simulation were employed, in whom in two of nine occlusion of the shunt occured. The anatomic extent of isolation of internal mammary artery was in the group of patients in whom the 3D MRI-based design of surgey was employed as long as 20–35 mm, in average 29 ± 6 mm, whereas in patients without 3D anatomic simulation and design it was over 30 mm in all cases. Conclusion. Thus, the use of simultaneous MRA imaging of coronary and internal mammary arteries significantly improved both technique of mammarocoronary bypassing itself and provided no cases of shunt occlusion during the one-year folow-up.
More
Translated text
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined