Optimisation of a Model Based Controlled Power Converter Test Platform

PCIM Europe 2023; International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management(2023)

Cited 0|Views0
No score
Abstract
In order to identify the weak points in power converters for e. g. wind energy plants, a full-scale test rig with a maximum power of 10 MW and a climate chamber has been set up. There, entire switch cabinets can be tested under realistic climatic conditions and with varying electrical loads. The behaviour of the wind turbine generator is to be emulated by the frequency converter. Therefore, a model-based approach was chosen. Since there are no rotating machines in this test stand, the shaft angle must be extracted from the calculation model and transferred to the DUT. Within this work the overall process of modelling, parametrisation and coupling of the DUT based on emulated encoder signals will be optimised towards a fully functional test platform for power converters.
More
Translated text
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper