Black-Blood Magnetization Prepared 2 Rapid Acquisition Gradient Echoes: A Fast and Three-Dimensional MR Black-Blood T1 Mapping Technique for Quantitative Assessment of Atherosclerosis and Venous Thrombosis

Yuhui Nie,Na Lu, Liping Liao, Zeping Liu, Anyan Gu, Xin Huang,Changjun Tie,Hongyan Liu,Zehe Huang,Guoxi Xie

Journal of magnetic resonance imaging : JMRI(2023)

引用 0|浏览9
暂无评分
摘要
Background: Blood flow signals may be a confounder in quantifying T-1 values of plaque or thrombus and how to realize black-blood T-1 mapping remains a challenge task.Purpose: To develop a fast and three-dimensional black-blood T-1 mapping technique for quantitative assessment of atherosclerosis and venous thrombosis.Study type: Sequence development and optimization via phantoms and volunteers as well as pilot prospective.Phantom and subjects: Numerical simulations, a standard phantom, 8 healthy volunteers (mean age, 22 +/- 1 years; 5 males), and 19 patients (mean age, 57 +/- 14 years; 13 males) with atherosclerosis or venous thrombosis.Field strength/sequence: 3T/inversion recovery spin-echo sequence (IR-SE), magnetization prepared 2 rapid acquisition gradient echoes (MP2RAGE), and black-blood prepared MP2RAGE (BB-MP2RAGE).Assessment: The black-blood preparation (i.e., delay alternating with nutation for tailored excitation, DANTE) was incorporated into MP2RAGE for black-blood T-1 mapping. The BB-MP2RAGE was optimized numerically based on the Bloch equation, and then the phantom study was performed to verify the accuracy of T-1 mapping by BB-MP2RAGE against IR-SE and MP2RAGE. Preliminary clinical validation was prospectively performed to assess the flow suppression effect and its potential application in plaque and thrombosis identification.Statistical tests: Pearson correlation test, Bland-Altman analysis, paired t-test, and intraclass correlation coefficient. A P value <0.05 indicates a statistically significant difference.Results: Phantom experiments showed comparable accuracy of T-1 maps by BB-MP2RAGE with IR-SE and MP2RAGE (all r(2) > 0.99); Compared to MP2RAGE, BB-MP2RAGE effectively nulled the blood flow signals, and had a significant improvement in contrast-to-noise ratio between static tissue and blood (250.5 +/- 66.6 vs. 91.9 +/- 35.9). BB-MP2RAGE can quantify plaque or thrombus T-1 relaxation time with blood flow signal suppression.Data conclusion: Accurate T-1 mapping with sufficient blood flow suppression was achieved by BB-MP2RAGE. BB-MP2RAGE has the potential to quantitatively characterize atherosclerosis and venous thrombosis.
更多
查看译文
关键词
black-blood imaging,T-1 mapping,atherosclerosis,venous thrombosis
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要