Flat-Plate PHP with Gravity-Independent Performance and High Maximum Thermal Load

Markus Winkler, Marc Vergez, Andreas Mahlke, Mathias Gebauer, Phillip Mueller, Christoph Reising, Kilian Bartholome, Olaf Schaefer-Welsen

ENERGIES(2023)

引用 0|浏览4
暂无评分
摘要
In many energy-related applications, components with high heat loads, such as power electronics, play an important role. Pulsating heat pipes (PHPs) are an effective solution to deal with the increasing heat load of these components. In many real-life applications, the PHP must work against gravity and still be able to operate efficiently. However, the majority of present flat-plate PHP designs do not perform well under this condition. Therefore, this paper presents a flat-plate PHP with a conventional channel design optimized for gravity-independent operation. The PHP was capable of transmitting a heat output of 754 watts in all orientations, while the testing heater in use never exceeded a temperature of 100 degrees C. No indications of dryout were observed, implying that the maximum thermal load the PHP can handle is even higher. Additionally, three different condenser zone sizes were tested with the PHP. Previously published results indicated that there is a specific range of suitable condenser zone sizes, and performance problems will occur if the condenser zone size falls outside of this range. The findings from this work point in the same direction.
更多
查看译文
关键词
pulsating heat pipes,oscillating heat pipes,cooling,heat transfer,thermal resistance,electronics cooling