Chrome Extension
WeChat Mini Program
Use on ChatGLM

Anatomical and functional results after vitrectomy with conventional ILM peeling versus inverted ILM flap technique in large full-thickness macular holes

International journal of retina and vitreous(2023)

Cited 0|Views6
No score
Abstract
Background Aim of the study was to compare success rate and functional outcome following pars plana vitrectomy (PPV) with conventional internal limiting membrane (ILM) peeling versus ILM flap technique for full-thickness idiopathic macular holes (FTMH). Methods Retrospective analysis of consecutive eyes with FTMH having undergone vitrectomy with sulfur hexafluoride (SF6) endotamponade 25% at the University Medical Center Rostock, Germany (2009–2020). Eyes were divided according to applied surgical technique (ILM peeling [group P] versus ILM flap [group F]). Inclusion criteria were macular hole base diameters (MH-BD) ≥ 400 μm plus axial length ≤ 26.0 mm. Each group was divided into two subgroups based on macular hole minimum linear diameter (MH-MLD): ≤ 400 μm and > 400 μm. Exclusion criteria were FTMH with MH-BD < 400 μm, trauma, myopia with axial length > 26.0 mm or macular schisis. Demographic, functional, and anatomical data were obtained pre- and postoperatively. Preoperative MH-BD and MH-MLD were measured using optical coherence tomography (OCT; Spectralis®, Heidelberg Engineering GmbH, Heidelberg, Germany). Main outcome parameter were: primary closure rate, best-corrected visual acuity (BCVA), and re-surgery rate. Results Overall 117 eyes of 117 patients with FTMH could be included, thereof 52 eyes underwent conventional ILM peeling (group P) and 65 additional ILM flap (group F) technique. Macular hole closure was achieved in 31 eyes (59.6%) in group P and in 59 eyes (90.8%) in group F (p < 0.001). Secondary PPV was required in 21 eyes (40.4%) in group P and in 6 eyes (9.2%) in group F. Postoperative BCVA at first follow-up in eyes with surgical closure showed no significant difference for both groups (MH-MLD ≤ 400 μm: p = 0.740); MH-MLD > 400 μm: p = 0.241). Conclusion Anatomical results and surgical closure rate following ILM flap technique seems to be superior to conventional ILM peeling for treatment of FTMH.
More
Translated text
Key words
Macular hole,Vitrectomy,ILM flap,ILM peeling,Endotamponade,Surgery
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined