Accurate and nonuniform CFD-based thermal behavior analysis of distribution transformers: voltage imbalance effect

JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING(2023)

Cited 0|Views1
No score
Abstract
Thermal condition monitoring of distribution transformers (DTs) as the most important and expensive equipment of the power grid is undeniable, and by accurate investigation of its thermal status, its failure can be prevented because the insulation condition of the transformer is directly related to the hotspot temperature (HST). In this paper, accurate and nonuniform magnetic-thermal analysis of DT is proposed for precise HST prediction. In the magnetic analysis, the DT is modeled as a 2D axial symmetry, and the losses calculation of the windings has been fulfilled as a nonuniform. In the thermal analysis, the DT is modeled as 3D and nonuniform, and the conservator and core stacking, which has a considerable effect on the HST, is precisely modeled. By taking advantage of optical fiber sensors (OFSs) in the understudied 500 kVA DT, the accuracy of the proposed nonuniform 3D CFD-based modeling during the temperature rise test (TRT) is validated. The empirical evaluation results depict that the presented nonuniform CFD-based thermal analysis for HST prediction is very precise, and there is an appropriate vicinity to the experimental values. The error percentage of the proposed 3D CFD-based thermal analysis is 0.11% (0.1 °C) compared to the OFSs measurements, which demonstrates the precision and effectiveness of the presented modeling. Also, the verification of the results of nonuniform 3D CFD-based thermal analysis in top-oil temperature (TOT) and bottom-oil temperature (BOT) during the experimental TRT is fulfilled via thermography. According to the attained evaluated results, temperatures of 3D CFD-based thermal analysis and thermography in the noted two points are in good accordance with each other. In short, the error percentage is less than 0.65%, which indicates the correctness and proper performance of the proposed nonuniform 3D CFD-based modeling. Finally, the proposed nonuniform 3D model was subjected to voltage imbalance of 0.95, 1.05, 1.1, 1.15, and 1.2 of rated voltage. The results demonstrate the HST increases by − 0.4, 0.4, 0.9, 1.3, and 1.8 °C, respectively, over the original model without voltage imbalance, which represents that this issue should be considered in the design and operation of the DT.
More
Translated text
Key words
Distribution transformer (DT),Hotspot temperature (HST),Nonuniform magnetic-thermal analysis,Computational fluid dynamic (CFD),Heat transfer,Optical fiber sensor (OFS),Thermography
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined